Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 6,169–6,192 of 10,248
Embraco ESX55CBC (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.07 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco ESY55CBP (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.08 kW input, COP 1.47 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FF10HBK (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.83 kW cooling, 0.46 kW input, COP 1.80 at the AHRI 7.2/54.4 °C rating point.
Embraco FF10HBK (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 1.1 kW cooling, 0.47 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.
Embraco FF10HBK (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.83 kW cooling, 0.46 kW input, COP 1.80 at the AHRI 7.2/54.4 °C rating point.
Embraco FF10HBX (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.85 kW cooling, 0.47 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
Embraco FF10HBX (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 1.1 kW cooling, 0.47 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.
Embraco FF10HBX (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.85 kW cooling, 0.47 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
Embraco FF6HBK (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.60 kW cooling, 0.32 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
Embraco FF6HBK (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.75 kW cooling, 0.32 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
Embraco FF6HBK (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.60 kW cooling, 0.32 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
Embraco FF7,5HBK (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.64 kW cooling, 0.36 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
Embraco FF7,5HBK (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.68 kW cooling, 0.30 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
Embraco FF7,5HBK (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.81 kW cooling, 0.36 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.
Embraco FF7,5HBK (R134a hermetic, MBP, EN12900, 50-60 Hz)
R134a compressor — 0.54 kW cooling, 0.30 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point.
Embraco FF7,5HBK (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.64 kW cooling, 0.36 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
Embraco FF8,5HBK (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 0.67 kW cooling, 0.34 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.
Embraco FF8,5HBK (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.75 kW cooling, 0.41 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
Embraco FF8,5HBK (R134a hermetic, LBP, ASHRAE, 50 Hz)
R134a compressor — 0.84 kW cooling, 0.34 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point.
Embraco FF8,5HBK (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.94 kW cooling, 0.41 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.
Embraco FF8,5HBK (R134a hermetic, MBP, EN12900, 50 Hz)
R134a compressor — 0.67 kW cooling, 0.34 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.
Embraco FF8,5HBK (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.75 kW cooling, 0.41 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
Embraco FFC110HBX (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 1.1 kW cooling, 0.48 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
Embraco FFC110HBX (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 1.1 kW cooling, 0.48 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one