Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 6,217–6,240 of 10,248
Embraco FFI7,5HAK (R134a hermetic, MBP, EN12900, 50-60 Hz)
R134a compressor — 0.16 kW cooling, 0.14 kW input, COP 1.14 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFI7,5HAK (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.16 kW cooling, 0.13 kW input, COP 1.22 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFI8,5HAK (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.19 kW cooling, 0.14 kW input, COP 1.30 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFI8,5HAK (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.19 kW cooling, 0.14 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFI8,5HAK (R134a hermetic, MBP, EN12900, 50-60 Hz)
R134a compressor — 0.17 kW cooling, 0.14 kW input, COP 1.19 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFI8,5HAK (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.18 kW cooling, 0.14 kW input, COP 1.30 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU100HAK (R134a hermetic, LBP, ASHRAE, 50-60 Hz)
R134a compressor — 0.23 kW cooling, 0.14 kW input, COP 1.59 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU100HAK (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.23 kW cooling, 0.15 kW input, COP 1.48 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU100HAK (R134a hermetic, MBP, EN12900, 50-60 Hz)
R134a compressor — 0.21 kW cooling, 0.14 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU100HAK (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.21 kW cooling, 0.15 kW input, COP 1.36 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130HAX (R134a hermetic, LBP, ASHRAE, 50 Hz)
R134a compressor — 0.25 kW cooling, 0.17 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130HAX (R134a hermetic, LBP, ASHRAE, 60 Hz)
R134a compressor — 0.28 kW cooling, 0.21 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130HAX (R134a hermetic, MBP, EN12900, 50 Hz)
R134a compressor — 0.22 kW cooling, 0.17 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130HAX (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.26 kW cooling, 0.21 kW input, COP 1.22 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130LAS (R1234yf hermetic, LBP, EN12900, 50 Hz)
R1234yf compressor — 0.24 kW cooling, 0.18 kW input, COP 1.28 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130LAS (R1234yf hermetic, MBP, EN12900, 50 Hz)
R1234yf compressor — 0.24 kW cooling, 0.18 kW input, COP 1.28 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130UAX (R290 hermetic, LBP, EN12900, 50-60 Hz)
R290 compressor — 0.29 kW cooling, 0.20 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130UAX (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.30 kW cooling, 0.22 kW input, COP 1.34 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130UAX (R290 hermetic, MBP, EN12900, 50-60 Hz)
R290 compressor — 0.29 kW cooling, 0.20 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU130UAX (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.30 kW cooling, 0.22 kW input, COP 1.34 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU160HAX (R134a hermetic, LBP, EN12900, 50 Hz)
R134a compressor — 0.27 kW cooling, 0.21 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU160HAX (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.32 kW cooling, 0.25 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU160HAX (R134a hermetic, MBP, EN12900, 50 Hz)
R134a compressor — 0.27 kW cooling, 0.21 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FFU160HAX (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.32 kW cooling, 0.25 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one