Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 6,505–6,528 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Invotech YH95C7-100 (R410A air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR410A compressor — 11.4 kW cooling, 3.82 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AGB4581ZTZ (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 16.6 kW cooling, 7.36 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DJNF11ME-TSK (R407F Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR407F compressor — 20.1 kW cooling, 13.11 kW input, COP 1.53 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HLH068T7A (R454B scroll, 60 Hz) CatalogCompressorsDanfossR454B compressor — 18.9 kW cooling, 5.90 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X1121U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.11 kW cooling, 0.09 kW input, COP 1.24 at -40/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH95C8-100 (R410A air-conditioning scroll, 60 Hz, 575 V 3P) CatalogCompressorsInvotechR410A compressor — 11.4 kW cooling, 3.82 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2464P-TZ1A (R448A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 0.81 kW cooling, 0.81 kW input, COP 0.99 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DJNR40ME-AWX (R134A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR134a compressor — 90.0 kW cooling, 28.92 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HLJ083T2A (R454B scroll, 60 Hz) CatalogCompressorsDanfossR454B compressor — 23.3 kW cooling, 7.22 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT56CLP (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.12 kW cooling, 0.09 kW input, COP 1.27 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4522Z-XG1A (R448A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 5.7 kW cooling, 2.21 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DJXF11ML-TSK (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 26.1 kW cooling, 14.75 kW input, COP 1.77 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH034U2A (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 10.0 kW cooling, 3.38 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMX6181U (R290 hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.84 kW cooling, 0.33 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4440Y-FZ1A (R134a hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 1.1 kW cooling, 0.45 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DJXR40ME-TSN (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 135.1 kW cooling, 45.77 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HRM045U2 (R22 scroll, 50 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 10.9 kW cooling, 3.46 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY70HER (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.16 kW cooling, 0.11 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4537N-TZ1A (R134a hermetic, HBP, Tecumseh Europe, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 10.7 kW cooling, 3.91 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DKNF93KL-TSK (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 21.6 kW cooling, 12.44 kW input, COP 1.73 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRP051T7 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 12.1 kW cooling, 3.83 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6187Y (R600a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.81 kW cooling, 0.38 kW input, COP 2.12 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB4581ZTZ (R448A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 19.6 kW cooling, 9.31 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DKNR35ME-TSK (R407F Discus recip, 50 Hz, AC) CatalogCompressorsCopelandR407F compressor — 97.0 kW cooling, 30.66 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
‹ Previous1…270271272273274…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one