Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 6,721–6,744 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss HLJ083T4A (R410A scroll, 50 Hz) CatalogCompressorsDanfossR410A compressor — 18.2 kW cooling, 6.27 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X3113U (R290 hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.16 kW cooling, 0.10 kW input, COP 1.63 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4546P-TZ1A (R404A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 11.4 kW cooling, 5.58 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland CR17K9M-PFV (R22 hermetic recip, 60 Hz, HT) CatalogCompressorsCopelandR22 compressor — 4.9 kW cooling, 1.52 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HRH034U4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 8.5 kW cooling, 2.90 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT6152GK (R404A hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 0.62 kW cooling, 0.33 kW input, COP 1.88 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB5561EKZ (R22 hermetic, AC, Tecumseh Europe, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 14.9 kW cooling, 5.08 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland CS10KIE-PFV (R404A hermetic recip, 60 Hz, MT) CatalogCompressorsCopelandR404A compressor — 1.7 kW cooling, 1.13 kW input, COP 1.48 at -20/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM045U4 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 13.2 kW cooling, 4.01 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY80HLC (R134a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.14 kW cooling, 0.10 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464U-HZ3C (R290 hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR290 compressor — 0.88 kW cooling, 0.86 kW input, COP 1.02 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland KCE432HAG-SXH (R134A hermetic recip, 50 Hz, HT) CatalogCompressorsCopelandR134a compressor — 0.79 kW cooling, 0.37 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss HRP054T2 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 15.2 kW cooling, 4.73 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6210Z (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 1.1 kW cooling, 0.60 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4522Z-XN3A (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 4.7 kW cooling, 2.04 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland KCJ450LAL-B3H (R404A hermetic recip, 50 Hz, LT) CatalogCompressorsCopelandR404A compressor — 0.45 kW cooling, 0.54 kW input, COP 0.84 at -35/50 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Danfoss LLZ015T2A (R449A scroll, 60 Hz, LT) CatalogCompressorsDanfossR449A compressor — 3.8 kW cooling, 2.85 kW input, COP 1.32 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco NT6222GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 2.7 kW cooling, 1.31 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4440Z-FZ1A (R449A hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 1.0 kW cooling, 0.42 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland KCM514CAL-B3H (R404A hermetic recip, 50 Hz, MT) CatalogCompressorsCopelandR404A compressor — 6.4 kW cooling, 2.45 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss MLZ015T2C (R455A scroll, 60 Hz) CatalogCompressorsDanfossR455A compressor — 6.3 kW cooling, 2.26 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X3113U (R290 hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.13 kW cooling, 0.08 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4546P-TZ1A (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 9.9 kW cooling, 4.07 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland KCN413CAG-V3H (R134A hermetic recip, 60 Hz, MT) CatalogCompressorsCopelandR134a compressor — 0.65 kW cooling, 0.26 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
‹ Previous1…279280281282283…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one