Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 6,697–6,720 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Danfoss SM160-7 (R22 scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 39.1 kW cooling, 11.60 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NT6220ZV (R134a hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 2.2 kW cooling, 1.08 kW input, COP 2.03 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AE4440Z-FZ1A (R404A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R404A compressor — 1.1 kW cooling, 0.46 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland AFE08C4E-IAZ (R449A hermetic recip, 50 Hz, LT) Catalog | Compressors | Copeland | R449A compressor — 0.20 kW cooling, 0.17 kW input, COP 1.16 at -25/40 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss SZ115-4 (R404A scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R404A compressor — 29.2 kW cooling, 11.62 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2X3113U (R290 hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R290 compressor — 0.13 kW cooling, 0.08 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AG4546P-TZ1A (R404A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R404A compressor — 9.5 kW cooling, 4.39 kW input, COP 2.17 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland AFF10C1E-IA3 (R134A hermetic recip, 60 Hz, EF) Catalog | Compressors | Copeland | R134a compressor — 0.34 kW cooling, 0.25 kW input, COP 1.34 at -25/40 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss VZH052CH (R410A inverter scroll, A/C) Catalog | Compressors | Danfoss | R410A compressor — 27.4 kW cooling, 9.39 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMT6144Z (R134a hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.52 kW cooling, 0.22 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AGB5561ECZ (R22 hermetic, AC, Tecumseh Europe, 60 Hz) Catalog | Compressors | Tecumseh | R22 compressor — 17.5 kW cooling, 6.65 kW input, COP 2.64 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ARE17C4E-IAA (R450A hermetic recip, 60 Hz, HT) Catalog | Compressors | Copeland | R450A compressor — 0.47 kW cooling, 0.26 kW input, COP 1.83 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss DCJ121T4A (R454B scroll, 50 Hz) Catalog | Compressors | Danfoss | R454B compressor — 25.4 kW cooling, 8.58 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMY80CLP (R600a hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.15 kW cooling, 0.10 kW input, COP 1.42 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AJ2464U-FZ3C (R290 hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R290 compressor — 0.73 kW cooling, 0.72 kW input, COP 1.01 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland ASE14C4E-IAA (R404A hermetic recip, 60 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 0.30 kW cooling, 0.30 kW input, COP 1.01 at -20/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss DSF530-3 (R32 scroll, 60 Hz, HT) Catalog | Compressors | Danfoss | R32 compressor — 156.3 kW cooling, 45.56 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NEK6210U (R290 hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R290 compressor — 1.1 kW cooling, 0.57 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh FH4522Z-XN3A (R449A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R449A compressor — 5.6 kW cooling, 2.23 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ASM16C1U-RAA (R290 hermetic recip, 60 Hz, EM) Catalog | Compressors | Copeland | R290 compressor — 0.26 kW cooling, 0.15 kW input, COP 1.68 at -25/40 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss DSH140-4 (R452B scroll, 50 Hz, HT) Catalog | Compressors | Danfoss | R452B compressor — 30.4 kW cooling, 10.31 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NT6222GK (R404A hermetic, MBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R404A compressor — 2.1 kW cooling, 1.19 kW input, COP 1.72 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AE4440Z-FZ1A (R448A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R448A compressor — 1.0 kW cooling, 0.42 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland CF09K7ME-TFD (R404A hermetic recip, 50 Hz, LT) Catalog | Compressors | Copeland | R404A compressor — 2.0 kW cooling, 1.58 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one