Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 6,817–6,840 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss MTZ018-5 (R407C hermetic reciprocating, 50 Hz, HT) CatalogCompressorsDanfossR407C compressor — 3.6 kW cooling, 1.40 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT6224GK (R404A hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 2.5 kW cooling, 1.28 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4450E-FZ1B (R22 hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 1.2 kW cooling, 0.50 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland YF03KAE-TF5 (R455A scroll, 50 Hz, LT) CatalogCompressorsCopelandR455A compressor — 0.51 kW cooling, 0.52 kW input, COP 0.99 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss NTZ096-4B (R404A hermetic reciprocating, 50 Hz, LT) CatalogCompressorsDanfossR404A compressor — 1.1 kW cooling, 1.29 kW input, COP 0.86 at -40/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EM2X3117U (R290 hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.21 kW cooling, 0.12 kW input, COP 1.71 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4546P-TZ1A (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 9.6 kW cooling, 4.25 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland YFD32KAE-TFD (R454C scroll, 50 Hz, LL) CatalogCompressorsCopelandR454C compressor — 7.0 kW cooling, 4.99 kW input, COP 1.39 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss PSH026-4G (R454B scroll, 50 Hz) CatalogCompressorsDanfossR454B compressor — 27.5 kW cooling, 9.48 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT6170Z (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.70 kW cooling, 0.36 kW input, COP 1.95 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB5568ETZ (R22 hermetic, AC, Tecumseh Europe, 60 Hz) CatalogCompressorsTecumsehR22 compressor — 19.6 kW cooling, 7.69 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland YFH03KAE-TF5 (R407C scroll, 50 Hz, LT) CatalogCompressorsCopelandR407C compressor — 0.50 kW cooling, 0.57 kW input, COP 0.89 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss SH240-4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 53.2 kW cooling, 18.50 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6213U (R290 hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 1.3 kW cooling, 0.69 kW input, COP 1.92 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464Z-FZ3C (R449A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 0.82 kW cooling, 0.87 kW input, COP 0.94 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland YH06K1E-TFD (R454C scroll, 60 Hz, HP) CatalogCompressorsCopelandR454C compressor — 8.3 kW cooling, 2.83 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SM160-9 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 47.7 kW cooling, 14.22 kW input, COP 3.36 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT6224GKV (R404A hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 3.0 kW cooling, 1.57 kW input, COP 1.88 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4524P-KZ1A (R455A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR455A compressor — 6.3 kW cooling, 2.39 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland YP195KPT-TFM (R32 scroll, 50 Hz, AC) CatalogCompressorsCopelandR32 compressor — 42.4 kW cooling, 14.75 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss SZ115-4 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 32.8 kW cooling, 10.22 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X3121U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.22 kW cooling, 0.13 kW input, COP 1.78 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4450N-FZ1C (R1234yf hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR1234yf compressor — 1.3 kW cooling, 0.56 kW input, COP 2.37 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland YS09KAE-PFJ (R407A scroll, 50 Hz, EM) CatalogCompressorsCopelandR407A compressor — 1.1 kW cooling, 0.82 kW input, COP 1.36 at -25/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
‹ Previous1…283284285286287…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one