Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.

Suppliers 26Systems 3,346Components 10,248
All kindsCompressor 9,761Pump 260Fan 173Heater 40Evaporative media 5Recovery core 5Heat pipe 3Coil 1
All marketsEU 5,807NA 4,975APAC 3,696CN 1,283LATAM 1,283MEA 1
All tagsR404A 1,129R134a 1,064R407C 941R448A 845R22 735R449A 661R290 541R410A 506R407F 479R407A 477R454C 348R455A 342+13 more — search by name instead
All suppliersCopeland 5,452Tecumseh 1,891Embraco 1,283Invotech 1,103Grundfos 223Ziehl-Abegg 171KSB 33Bitzer 25Powrmatic 22Reznor 6Systemair 6Recair 5+9 more — search by name instead
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 7,321–7,344 of 10,248

Invotech YH133T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140A1-100 (R22 air-conditioning scroll, 50 Hz, 380 V 3P)

R22 compressor — 14.1 kW cooling, 4.11 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YH140A1-100 (R22 air-conditioning scroll, 60 Hz, 460 V 3P)

R22 compressor — 16.9 kW cooling, 4.94 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140A2-100 (R22 air-conditioning scroll, 50 Hz, 220 V 1P)

R22 compressor — 14.1 kW cooling, 4.27 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YH140A3-100 (R22 air-conditioning scroll, 60 Hz, 220 V 1P)

R22 compressor — 16.9 kW cooling, 5.13 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140A5-100 (R22 air-conditioning scroll, 60 Hz, 380 V 3P)

R22 compressor — 16.9 kW cooling, 4.94 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140A6-100 (R22 air-conditioning scroll, 50 Hz, 220 V 3P)

R22 compressor — 14.1 kW cooling, 4.11 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YH140A7-100 (R22 air-conditioning scroll, 60 Hz, 220 V 3P)

R22 compressor — 16.9 kW cooling, 4.94 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140A8-100 (R22 air-conditioning scroll, 60 Hz, 575 V 3P)

R22 compressor — 16.9 kW cooling, 4.94 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140T1-100 (R407C air-conditioning scroll, 50 Hz, 380 V 3P)

R407C compressor — 13.5 kW cooling, 4.16 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH140T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T2-100 (R407C air-conditioning scroll, 50 Hz, 220 V 1P)

R407C compressor — 13.5 kW cooling, 4.31 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH140T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P)

R407C compressor — 16.2 kW cooling, 5.18 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T5-100 (R407C air-conditioning scroll, 60 Hz, 380 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T6-100 (R407C air-conditioning scroll, 50 Hz, 220 V 3P)

R407C compressor — 13.5 kW cooling, 4.16 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH140T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH150A1-100 (R22 air-conditioning scroll, 50 Hz, 380 V 3P)

R22 compressor — 15.1 kW cooling, 4.41 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YH150A1-100 (R22 air-conditioning scroll, 60 Hz, 460 V 3P)

R22 compressor — 18.1 kW cooling, 5.29 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH150A2-100 (R22 air-conditioning scroll, 50 Hz, 220 V 1P)

R22 compressor — 15.1 kW cooling, 4.58 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YH150A3-100 (R22 air-conditioning scroll, 60 Hz, 220 V 1P)

R22 compressor — 18.1 kW cooling, 5.49 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH150A5-100 (R22 air-conditioning scroll, 60 Hz, 380 V 3P)

R22 compressor — 18.1 kW cooling, 5.29 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH150A6-100 (R22 air-conditioning scroll, 50 Hz, 220 V 3P)

R22 compressor — 15.1 kW cooling, 4.41 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU
‹ Previous1…304305306307308…427Next ›