Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.

Suppliers 26Systems 3,346Components 10,248
All kindsCompressor 9,761Pump 260Fan 173Heater 40Evaporative media 5Recovery core 5Heat pipe 3Coil 1
All marketsEU 5,807NA 4,975APAC 3,696CN 1,283LATAM 1,283MEA 1
All tagsR404A 1,129R134a 1,064R407C 941R448A 845R22 735R449A 661R290 541R410A 506R407F 479R407A 477R454C 348R455A 342+13 more — search by name instead
All suppliersCopeland 5,452Tecumseh 1,891Embraco 1,283Invotech 1,103Grundfos 223Ziehl-Abegg 171KSB 33Bitzer 25Powrmatic 22Reznor 6Systemair 6Recair 5+9 more — search by name instead
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 7,369–7,392 of 10,248

Invotech YH175C1-100 (R410A air-conditioning scroll, 50 Hz, 380 V 3P)

R410A compressor — 17.5 kW cooling, 5.60 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YH175C1-100 (R410A air-conditioning scroll, 60 Hz, 460 V 3P)

R410A compressor — 20.9 kW cooling, 6.71 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · NA

Invotech YH175C5-100 (R410A air-conditioning scroll, 60 Hz, 380 V 3P)

R410A compressor — 20.9 kW cooling, 6.71 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · NA

Invotech YH175C6-100 (R410A air-conditioning scroll, 50 Hz, 220 V 3P)

R410A compressor — 17.5 kW cooling, 5.60 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YH175C7-100 (R410A air-conditioning scroll, 60 Hz, 220 V 3P)

R410A compressor — 20.9 kW cooling, 6.71 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · NA

Invotech YH175C8-100 (R410A air-conditioning scroll, 60 Hz, 575 V 3P)

R410A compressor — 20.9 kW cooling, 6.71 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · NA

Invotech YH175T1-100 (R407C air-conditioning scroll, 50 Hz, 380 V 3P)

R407C compressor — 16.9 kW cooling, 5.15 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH175T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P)

R407C compressor — 20.3 kW cooling, 6.19 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH175T5-100 (R407C air-conditioning scroll, 60 Hz, 380 V 3P)

R407C compressor — 20.3 kW cooling, 6.19 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH175T6-100 (R407C air-conditioning scroll, 50 Hz, 220 V 3P)

R407C compressor — 16.9 kW cooling, 5.15 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH175T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P)

R407C compressor — 20.3 kW cooling, 6.19 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH175T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P)

R407C compressor — 20.3 kW cooling, 6.19 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH183C1-100 (R410A air-conditioning scroll, 50 Hz, 380 V 3P)

R410A compressor — 18.5 kW cooling, 5.86 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YH183C1-100 (R410A air-conditioning scroll, 60 Hz, 460 V 3P)

R410A compressor — 22.2 kW cooling, 7.04 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · NA

Invotech YH183C5-100 (R410A air-conditioning scroll, 60 Hz, 380 V 3P)

R410A compressor — 22.2 kW cooling, 7.04 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · NA

Invotech YH183C6-100 (R410A air-conditioning scroll, 50 Hz, 220 V 3P)

R410A compressor — 18.5 kW cooling, 5.86 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YH183C7-100 (R410A air-conditioning scroll, 60 Hz, 220 V 3P)

R410A compressor — 22.2 kW cooling, 7.04 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · NA

Invotech YH183C8-100 (R410A air-conditioning scroll, 60 Hz, 575 V 3P)

R410A compressor — 22.2 kW cooling, 7.04 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · NA

Invotech YH200A1-100 (R22 air-conditioning scroll, 50 Hz, 380 V 3P)

R22 compressor — 20.1 kW cooling, 5.91 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YH200A1-100 (R22 air-conditioning scroll, 60 Hz, 460 V 3P)

R22 compressor — 24.2 kW cooling, 7.11 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH200A5-100 (R22 air-conditioning scroll, 60 Hz, 380 V 3P)

R22 compressor — 24.2 kW cooling, 7.11 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH200A7-100 (R22 air-conditioning scroll, 60 Hz, 220 V 3P)

R22 compressor — 24.2 kW cooling, 7.11 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH200A8-100 (R22 air-conditioning scroll, 60 Hz, 575 V 3P)

R22 compressor — 24.2 kW cooling, 7.11 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH200C1-100 (R410A air-conditioning scroll, 50 Hz, 380 V 3P)

R410A compressor — 19.8 kW cooling, 6.23 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU