Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 7,393–7,416 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4461N-CZ1A (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 1.4 kW cooling, 0.73 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YUXR48ML-AWD (R455A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR455A compressor — 82.9 kW cooling, 30.46 kW input, COP 2.72 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ015T2C (R454A scroll, 50 Hz) CatalogCompressorsDanfossR454A compressor — 3.9 kW cooling, 2.68 kW input, COP 1.46 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh FH4525N-XG1A (R1234yf hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR1234yf compressor — 4.6 kW cooling, 1.87 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YVXF10ME-TSE (R449A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR449A compressor — 31.9 kW cooling, 18.29 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T4 (R407C scroll, 50 Hz, MT) CatalogCompressorsDanfossR407C compressor — 5.7 kW cooling, 1.86 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AE4456Y-XN3C (R513A hermetic, HBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR513A compressor — 1.8 kW cooling, 0.76 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YVXR48ME-TSE (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 82.8 kW cooling, 30.25 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT056-9 (R22 hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 16.5 kW cooling, 5.58 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AG4565U-TZ1A (R290 hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR290 compressor — 16.3 kW cooling, 6.37 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YZNF10ME-TSE (R448A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR448A compressor — 31.9 kW cooling, 18.29 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ019-1 (R407C hermetic reciprocating, 60 Hz) CatalogCompressorsDanfossR407C compressor — 5.0 kW cooling, 1.73 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4461N-CZ1A (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 1.7 kW cooling, 0.91 kW input, COP 1.87 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YZNR48ME-TSE (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 82.8 kW cooling, 30.25 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss NTZ108-3 (R404A hermetic reciprocating, 60 Hz, LT) CatalogCompressorsDanfossR404A compressor — 1.5 kW cooling, 2.04 kW input, COP 0.74 at -40/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh FH4525N-XG1A (R1234yf hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR1234yf compressor — 5.8 kW cooling, 2.40 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland AFE11C4E-IAV (R448A hermetic recip, 60 Hz, LT) CatalogCompressorsCopelandR448A compressor — 0.26 kW cooling, 0.23 kW input, COP 1.13 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH030-3G (R454B scroll, 60 Hz) CatalogCompressorsDanfossR454B compressor — 38.5 kW cooling, 12.51 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AE4460E-FZ1B (R22 hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 1.5 kW cooling, 0.67 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland AFF10C1E-IA3 (R513A hermetic recip, 60 Hz, EF) CatalogCompressorsCopelandR513A compressor — 0.35 kW cooling, 0.28 kW input, COP 1.24 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SH295-4 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 88.5 kW cooling, 27.21 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AG4568P-TZ1A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 14.1 kW cooling, 6.37 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ARE17C4E-IAA (R513A hermetic recip, 60 Hz, HT) CatalogCompressorsCopelandR513A compressor — 0.54 kW cooling, 0.32 kW input, COP 1.68 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SM185-4 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 54.3 kW cooling, 16.22 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…307308309310311…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one