Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 7,417–7,440 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Tecumseh AJ4461N-CZ1A (R513A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R513A compressor — 1.4 kW cooling, 0.73 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ASE14C4E-IAA (R448A hermetic recip, 60 Hz, MT) Catalog | Compressors | Copeland | R448A compressor — 0.27 kW cooling, 0.25 kW input, COP 1.08 at -20/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss SZ120-4 (R407C scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R407C compressor — 34.8 kW cooling, 10.75 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4525N-XG1A (R134a hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 5.0 kW cooling, 1.89 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ASM17C7U-IAA (R290 hermetic recip, 60 Hz, EM) Catalog | Compressors | Copeland | R290 compressor — 0.25 kW cooling, 0.17 kW input, COP 1.48 at -25/40 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss VZH065CGM (R452B inverter scroll) Catalog | Compressors | Danfoss | R452B compressor — 33.3 kW cooling, 12.05 kW input, COP 2.77 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AE4460N-FZ1C (R1234yf hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R1234yf compressor — 1.5 kW cooling, 0.66 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland CF09K7ME-TFD (R404A hermetic recip, 60 Hz, LT) Catalog | Compressors | Copeland | R404A compressor — 2.4 kW cooling, 1.85 kW input, COP 1.31 at -30/40 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss DSH161-3 (R454B scroll, 60 Hz, HT) Catalog | Compressors | Danfoss | R454B compressor — 46.0 kW cooling, 13.79 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AG4568P-TZ1A (R404A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R404A compressor — 16.9 kW cooling, 8.21 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland CR18K6-PFV (R22 hermetic recip, 50 Hz, AC) Catalog | Compressors | Copeland | R22 compressor — 4.3 kW cooling, 1.44 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss HLJ083T9 (R410A scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R410A compressor — 24.9 kW cooling, 7.71 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AJ4461N-CZ1A (R513A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R513A compressor — 1.7 kW cooling, 0.94 kW input, COP 1.79 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland CS11K6ME-TFD (R404A hermetic recip, 50 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 1.2 kW cooling, 0.96 kW input, COP 1.20 at -25/40 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss HRH036U9 (R410A scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R410A compressor — 10.7 kW cooling, 3.57 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4525N-XG1A (R134a hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 6.3 kW cooling, 2.42 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland KCE432HAG-SXH (R134A hermetic recip, 60 Hz, HT) Catalog | Compressors | Copeland | R134a compressor — 0.95 kW cooling, 0.47 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Danfoss HRM047U5 (R22 scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 11.6 kW cooling, 3.72 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AE4460P-FZ1B (R404A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R404A compressor — 1.3 kW cooling, 0.72 kW input, COP 1.84 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland KCJ461CAL-BXH (R404A hermetic recip, 50 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 2.8 kW cooling, 1.16 kW input, COP 2.45 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Danfoss HRP060T5 (R407C scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R407C compressor — 14.1 kW cooling, 4.46 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AG4568P-TZ1A (R448A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R448A compressor — 14.6 kW cooling, 5.91 kW input, COP 2.47 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland KCM514CAL-B5H (R134A hermetic recip, 50 Hz, MT) Catalog | Compressors | Copeland | R134a compressor — 4.0 kW cooling, 1.51 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Danfoss LLZ015T2C (R454A scroll, 60 Hz) Catalog | Compressors | Danfoss | R454A compressor — 5.0 kW cooling, 2.89 kW input, COP 1.74 at -30/30 °C (evaporating/condensing), inside its published envelope. | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one