Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 1,801–1,824 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh RG5512W-FZ4A (R407C hermetic, AC, EN12900, 50 Hz) CatalogCompressorsTecumsehR407C compressor — 2.2 kW cooling, 0.90 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YJXF84KE-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 29.2 kW cooling, 17.27 kW input, COP 1.69 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRP025T4 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 6.9 kW cooling, 2.21 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEGY6L (R1234yf variable-capacity hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR1234yf compressor — 0.18 kW cooling, 0.12 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF65A5G-V100 (R22 low-temperature freezing scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 25.3 kW cooling, 9.56 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh RGA5492CXA (R407C hermetic, AC, EN12900, 60 Hz) CatalogCompressorsTecumsehR407C compressor — 2.4 kW cooling, 0.85 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YKNF68KE-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 23.7 kW cooling, 13.93 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ013T2A (R448A scroll, 50 Hz, LT) CatalogCompressorsDanfossR448A compressor — 2.3 kW cooling, 1.79 kW input, COP 1.27 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco VEHT409U (R290 variable-capacity hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.49 kW cooling, 0.31 kW input, COP 1.59 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW120J1-100 (R134a heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR134a compressor — 13.4 kW cooling, 4.09 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh TA1340M-GS1A (R600a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR600a compressor — 0.06 kW cooling, 0.06 kW input, COP 0.95 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6YKNR32ME-TSK (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 116.4 kW cooling, 36.80 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLM019T4 (R22 scroll, 60 Hz, MT) CatalogCompressorsDanfossR22 compressor — 8.9 kW cooling, 2.78 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEHU413U (R290 variable-capacity hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.68 kW cooling, 0.46 kW input, COP 1.50 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF13E2G-V102 (R404A low-temperature freezing scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR404A compressor — 1.8 kW cooling, 1.57 kW input, COP 1.16 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh TC4410Y-DT1B (R513A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR513A compressor — 0.29 kW cooling, 0.15 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YKXF68KE-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 23.7 kW cooling, 13.93 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T1A (R134a scroll, 60 Hz, MT) CatalogCompressorsDanfossR134a compressor — 4.5 kW cooling, 1.55 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEMC7C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.12 kW cooling, 0.07 kW input, COP 1.69 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH119A7-100 (R22 air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 14.4 kW cooling, 4.25 kW input, COP 3.38 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh TCW350U-GS8B (R290 hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR290 compressor — 0.16 kW cooling, 0.10 kW input, COP 1.61 at -25/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6YKXR32ME-TSE (R454A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454A compressor — 61.6 kW cooling, 23.27 kW input, COP 2.65 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT018-5 (R22 hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 3.9 kW cooling, 1.45 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEMT403U (R290 variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.16 kW cooling, 0.11 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
‹ Previous1…7475767778…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one