Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 1,777–1,800 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Copeland 6YHNF68KL-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 23.7 kW cooling, 13.93 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLJ072T2A (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 21.2 kW cooling, 6.65 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NTX2211UV (R290 hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.89 kW cooling, 0.68 kW input, COP 1.32 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF65A4G-V100 (R22 low-temperature freezing scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR22 compressor — 25.1 kW cooling, 9.77 kW input, COP 2.57 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AWS2512ZTZ (R404A hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 1.8 kW cooling, 1.43 kW input, COP 1.28 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6YHNR32ML-TSK (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 116.4 kW cooling, 36.80 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HLM068T4 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 20.2 kW cooling, 5.94 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEG7C (R600a variable-capacity hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.11 kW cooling, 0.07 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW120J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR134a compressor — 11.2 kW cooling, 3.36 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh FH2480P-XC3A (R455A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR455A compressor — 1.00 kW cooling, 0.99 kW input, COP 1.01 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6YHXF68KE-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 23.7 kW cooling, 13.93 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLP072T1 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 20.4 kW cooling, 6.52 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEGC7H (R134a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.20 kW cooling, 0.13 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF13E2G-Q102 (R404A low-temperature freezing scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR404A compressor — 1.5 kW cooling, 1.39 kW input, COP 1.05 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh HG4512Z-FZ3A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 2.3 kW cooling, 1.04 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YJNF84KL-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 29.2 kW cooling, 17.27 kW input, COP 1.69 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH029U2 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 8.5 kW cooling, 2.84 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEGD7H (R134a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.21 kW cooling, 0.13 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH119A6-100 (R22 air-conditioning scroll, 50 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 12.0 kW cooling, 3.54 kW input, COP 3.38 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh HGA8510BXC (R410A hermetic, AC, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR410A compressor — 2.9 kW cooling, 0.82 kW input, COP 3.59 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YJNR39ME-TSN (R454A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454A compressor — 75.7 kW cooling, 28.61 kW input, COP 2.65 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM032U1 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 9.5 kW cooling, 2.91 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEGT11HB (R134a variable-capacity hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.31 kW cooling, 0.20 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM115E1G-100 (R404A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 17.8 kW cooling, 7.25 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
‹ Previous1…7374757677…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one