R404A compressor — 11.6 kW cooling, 3.84 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 8.1 kW cooling, 3.35 kW input, COP 2.43 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 9.9 kW cooling, 3.89 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 8.8 kW cooling, 4.13 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 12.7 kW cooling, 5.08 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 10.7 kW cooling, 5.00 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 12.3 kW cooling, 5.56 kW input, COP 2.22 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 13.3 kW cooling, 5.02 kW input, COP 2.64 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 11.9 kW cooling, 4.24 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 13.7 kW cooling, 4.92 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 8.7 kW cooling, 3.21 kW input, COP 2.71 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 10.3 kW cooling, 3.89 kW input, COP 2.66 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 12.7 kW cooling, 6.26 kW input, COP 2.03 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 14.9 kW cooling, 6.25 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 13.5 kW cooling, 4.74 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 15.4 kW cooling, 5.39 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 10.8 kW cooling, 3.92 kW input, COP 2.77 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 13.7 kW cooling, 4.72 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 18.2 kW cooling, 6.81 kW input, COP 2.67 at the AHRI 7.2/54.4 °C rating point.
R32 compressor — 12.0 kW cooling, 3.80 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.
R32 compressor — 108.7 kW cooling, 23.99 kW input, COP 4.53 at the AHRI 7.2/54.4 °C rating point.
R32 compressor — 13.4 kW cooling, 4.22 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.
R32 compressor — 16.2 kW cooling, 5.23 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 28.9 kW cooling, 9.95 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one