Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 2,041–2,064 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AH4540X-TZ1C (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 8.3 kW cooling, 3.86 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland KCM475LAL-CXX (R404A hermetic recip, 50 Hz, LT) CatalogCompressorsCopelandR404A compressor — 0.96 kW cooling, 1.06 kW input, COP 0.91 at -30/50 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Danfoss DSF100-4 (R32 scroll, 50 Hz, HT) CatalogCompressorsDanfossR32 compressor — 22.2 kW cooling, 7.87 kW input, COP 2.82 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFI10HAK (R134a hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.23 kW cooling, 0.17 kW input, COP 1.31 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH119C8-100 (R410A air-conditioning scroll, 60 Hz, 575 V 3P) CatalogCompressorsInvotechR410A compressor — 14.4 kW cooling, 4.71 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2428Z-XA1C (R449A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 0.31 kW cooling, 0.36 kW input, COP 0.86 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland KCN372LAG-BXH (R134A hermetic recip, 50 Hz, LT) CatalogCompressorsCopelandR134a compressor — 0.12 kW cooling, 0.13 kW input, COP 0.88 at -30/50 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Danfoss DSG480-4 (R1234ze(E) scroll, 50 Hz, MT) CatalogCompressorsDanfossR1234ze(E) compressor — 104.1 kW cooling, 32.07 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFU100HAK (R134a hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.21 kW cooling, 0.14 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM125A1G-100 (R22 medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 20.0 kW cooling, 6.70 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AJK480Z-TZ1C (R22 hermetic, HBP, Tecumseh Europe, 60 Hz) CatalogCompressorsTecumsehR22 compressor — 2.5 kW cooling, 1.13 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland RFT18C1E-PFA (R134A hermetic recip, 60 Hz, EM) CatalogCompressorsCopelandR134a compressor — 0.67 kW cooling, 0.53 kW input, COP 1.26 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH090-4 (R452B scroll, 60 Hz, A/C) CatalogCompressorsDanfossR452B compressor — 26.7 kW cooling, 8.38 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFUS100HAK (R134a hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.21 kW cooling, 0.15 kW input, COP 1.40 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF75E1G-V100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 25.3 kW cooling, 9.95 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AKA9438ZXD (R449A hermetic, HBP, ARI, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 1.6 kW cooling, 0.90 kW input, COP 1.73 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland RRT10K1E-PFV (R450A hermetic recip, 60 Hz, HT) CatalogCompressorsCopelandR450A compressor — 2.7 kW cooling, 1.15 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HCJ091T4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 22.4 kW cooling, 7.03 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFV7,5HAK (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.17 kW cooling, 0.12 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW135A7-100 (R22 heat-pump water heater scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 17.9 kW cooling, 5.53 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AL4480Z-FZ3B (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 1.9 kW cooling, 0.83 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland RST10K1E-PFV (R404A hermetic recip, 60 Hz, EM) CatalogCompressorsCopelandR404A compressor — 1.6 kW cooling, 1.16 kW input, COP 1.41 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HCM109T2 (R22 scroll, 50 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 26.7 kW cooling, 7.81 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FG95HAK (R134a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.19 kW cooling, 0.17 kW input, COP 1.10 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
‹ Previous1…8485868788…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one