Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 2,089–2,112 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Embraco FMXA6C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.51 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF13E7G-Q100 (R452A low-temperature freezing scroll, 60 Hz, 220 V 3P) Catalog | Compressors | Invotech | R452A compressor — 1.7 kW cooling, 1.64 kW input, COP 1.04 at -30/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Tecumseh RGA5510EXA (R22 hermetic, AC, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R22 compressor — 2.2 kW cooling, 0.80 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland VR108KF-TFP (R22 scroll, 50 Hz, AC) Catalog | Compressors | Copeland | R22 compressor — 26.4 kW cooling, 7.62 kW input, COP 3.46 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Danfoss HRH029U2A (R410A scroll, 60 Hz) Catalog | Compressors | Danfoss | R410A compressor — 8.2 kW cooling, 3.03 kW input, COP 2.71 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FMXC9C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH119T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P) Catalog | Compressors | Invotech | R407C compressor — 13.8 kW cooling, 4.29 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh TA1360M-GS1A (R600a hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R600a compressor — 0.08 kW cooling, 0.08 kW input, COP 1.00 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland VRI125KS-TFP (R22 scroll, 50 Hz, HI) Catalog | Compressors | Copeland | R22 compressor — 21.2 kW cooling, 7.49 kW input, COP 2.83 at -20/45 °C (evaporating/condensing), inside its published envelope. | APAC | Open in the builder |
| Danfoss HRM032U2 (R22 scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 9.3 kW cooling, 2.94 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FMXD6C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.09 kW cooling, 0.05 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM125A5G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 380 V 3P) Catalog | Compressors | Invotech | R22 compressor — 24.0 kW cooling, 8.03 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh TC4415Y-UZ1B (R134a hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 0.39 kW cooling, 0.18 kW input, COP 2.12 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland XHV0181P-9E9 (R410A variable-speed scroll) Catalog | Compressors | Copeland | R410A compressor — 7.6 kW cooling, 2.42 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Danfoss HRP032T1 (R407C scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R407C compressor — 9.0 kW cooling, 2.93 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FMXY6C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.08 kW cooling, 0.06 kW input, COP 1.42 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YSF75E5G-V100 (R404A low-temperature freezing scroll, 60 Hz, 380 V 3P) Catalog | Compressors | Invotech | R404A compressor — 30.4 kW cooling, 12.02 kW input, COP 2.53 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh TCW380U-CE3A (R290 hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R290 compressor — 0.21 kW cooling, 0.13 kW input, COP 1.60 at -25/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland XPV0182E-9E9 (R410A variable-speed scroll, 3 steps) Catalog | Compressors | Copeland | R410A compressor — 10.1 kW cooling, 3.43 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Danfoss LLZ013T2A (R449A scroll, 50 Hz, LT) Catalog | Compressors | Danfoss | R449A compressor — 2.3 kW cooling, 1.79 kW input, COP 1.27 at -35/30 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Embraco NE2121Z (R134a hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.24 kW cooling, 0.19 kW input, COP 1.28 at -25/45 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YW135C1-100 (R410A heat-pump water heater scroll, 60 Hz, 460 V 3P) Catalog | Compressors | Invotech | R410A compressor — 18.6 kW cooling, 6.23 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh THB4413YXA (R134a hermetic, HBP, ASHRAE, 60 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 0.38 kW cooling, 0.18 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland YA137K1E-TFD (R454B scroll, 50 Hz, AC) Catalog | Compressors | Copeland | R454B compressor — 33.7 kW cooling, 10.45 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one