Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 2,233–2,256 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss HLM072T2 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 21.3 kW cooling, 6.27 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VNEU217U (R290 variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.67 kW cooling, 0.58 kW input, COP 1.16 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW135T2-100 (R407C heat-pump water heater scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR407C compressor — 14.3 kW cooling, 4.82 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AJ2428Z-XA1C (R452A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 0.24 kW cooling, 0.31 kW input, COP 0.76 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland YS09KAE-PFJ (R134A scroll, 50 Hz, HT) CatalogCompressorsCopelandR134a compressor — 2.3 kW cooling, 0.85 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss HLP072T4 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 16.6 kW cooling, 5.30 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VNEX419U (R290 variable-capacity hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 1.0 kW cooling, 0.72 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF17A2G-Q102 (R22 low-temperature freezing scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR22 compressor — 1.8 kW cooling, 1.61 kW input, COP 1.13 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh AJK480Z-TZ1C (R404A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 2.2 kW cooling, 1.20 kW input, COP 1.84 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland YSH07KAE-TF5 (R404A scroll, 50 Hz, MT) CatalogCompressorsCopelandR404A compressor — 1.0 kW cooling, 0.61 kW input, COP 1.70 at -25/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HRH029U2A (R454B scroll, 50 Hz) CatalogCompressorsDanfossR454B compressor — 5.9 kW cooling, 2.42 kW input, COP 2.45 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EG70CLP (R600a hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.15 kW cooling, 0.13 kW input, COP 1.22 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH119T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P) CatalogCompressorsInvotechR407C compressor — 13.8 kW cooling, 4.29 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AKA9451ZXA (R404A hermetic, HBP, ARI, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 2.5 kW cooling, 1.35 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZB06KAE-TF5 (R134A scroll, 50 Hz, MT) CatalogCompressorsCopelandR134a compressor — 1.5 kW cooling, 0.55 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss HRM032U4 (R22 scroll, 50 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 7.9 kW cooling, 2.55 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EGAS100HLR (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.23 kW cooling, 0.15 kW input, COP 1.57 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM125E6G-100 (R404A medium-temperature refrigeration scroll, 50 Hz, 220 V 3P) CatalogCompressorsInvotechR404A compressor — 19.4 kW cooling, 7.52 kW input, COP 2.58 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AL4510Z-FZ3A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 2.2 kW cooling, 1.10 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZBD114K5E-TFD (R134A scroll, 50 Hz, HT) CatalogCompressorsCopelandR134a compressor — 27.7 kW cooling, 9.72 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss HRP034T1 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 9.6 kW cooling, 2.99 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EGUS70HLP (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.16 kW cooling, 0.11 kW input, COP 1.49 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF85E1G-V100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 29.1 kW cooling, 11.51 kW input, COP 2.53 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh ALX440U-FZ3C (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR290 compressor — 0.82 kW cooling, 0.52 kW input, COP 1.59 at -25/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
‹ Previous1…9293949596…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one