Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.

Suppliers 26Systems 3346Components 10248
All kindsCompressor 9761Pump 260Fan 173Heater 40Evaporative media 5Recovery core 5Heat pipe 3Coil 1
All marketsEU 5807NA 4975APAC 3696CN 1283LATAM 1283MEA 1
All tagsR404A 1129R134a 1064R407C 941R448A 845R22 735R449A 661R290 541R410A 506R407F 479R407A 477R454C 348R455A 342+13 more — search by name instead
All suppliersCopeland 5452Tecumseh 1891Embraco 1283Invotech 1103Grundfos 223Ziehl-Abegg 171KSB 33Bitzer 25Powrmatic 22Reznor 6Systemair 6Recair 5+9 more — search by name instead
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 2185–2208 of 10248

Copeland RST60C2U-CFA (R290 hermetic recip, 60 Hz, EM)

R290 compressor — 2.7 kW cooling, 1.23 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · NA

Copeland RST61C1E-CAV (R448A hermetic recip, 60 Hz, MT)

R448A compressor — 3.0 kW cooling, 1.22 kW input, COP 2.45 at the AHRI 7.2/54.4 °C rating point.

catalogR448A
Compressor · NA

Copeland RST61C1E-CAV (R449A hermetic recip, 60 Hz, MT)

R449A compressor — 3.0 kW cooling, 1.22 kW input, COP 2.45 at the AHRI 7.2/54.4 °C rating point.

catalogR449A
Compressor · NA

Copeland RST61C1E-CFA (R404A hermetic recip, 60 Hz, EM)

R404A compressor — 2.6 kW cooling, 1.52 kW input, COP 1.73 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Copeland RST64C1E-CAV (R448A hermetic recip, 60 Hz, MT)

R448A compressor — 3.3 kW cooling, 1.45 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.

catalogR448A
Compressor · NA

Copeland RST64C1E-CAV (R449A hermetic recip, 60 Hz, MT)

R449A compressor — 3.3 kW cooling, 1.45 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.

catalogR449A
Compressor · NA

Copeland RST64C1E-CAZ (R448A hermetic recip, 50 Hz, MT)

R448A compressor — 2.6 kW cooling, 1.18 kW input, COP 2.17 at the AHRI 7.2/54.4 °C rating point.

catalogR448A
Compressor · EU, APAC

Copeland RST64C1E-CAZ (R449A hermetic recip, 50 Hz, MT)

R449A compressor — 2.6 kW cooling, 1.18 kW input, COP 2.17 at the AHRI 7.2/54.4 °C rating point.

catalogR449A
Compressor · EU, APAC

Copeland RST68C2U-CFA (R290 hermetic recip, 60 Hz, EM)

R290 compressor — 3.0 kW cooling, 1.32 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · NA

Copeland RST68C2U-CFA (R454C hermetic recip, 60 Hz, EM)

R454C compressor — 2.9 kW cooling, 1.47 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.

catalogR454C
Compressor · NA

Copeland RST70C1E-PFA (R404A hermetic recip, 60 Hz, EM)

R404A compressor — 2.8 kW cooling, 1.42 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Copeland RST70C1E-PFV (R407C hermetic recip, 60 Hz, HT)

R407C compressor — 3.3 kW cooling, 1.30 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland RST70C1E-PFV (R448A hermetic recip, 60 Hz, MT)

R448A compressor — 3.1 kW cooling, 1.32 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.

catalogR448A
Compressor · NA

Copeland RST70C1E-PFV (R449A hermetic recip, 60 Hz, MT)

R449A compressor — 3.1 kW cooling, 1.32 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.

catalogR449A
Compressor · NA

Copeland RST80C1E-PFA (R404A hermetic recip, 60 Hz, EM)

R404A compressor — 3.4 kW cooling, 1.72 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Copeland RST80C1E-PFV (R448A hermetic recip, 60 Hz, MT)

R448A compressor — 3.6 kW cooling, 1.60 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.

catalogR448A
Compressor · NA

Copeland RST80C1E-PFV (R449A hermetic recip, 60 Hz, MT)

R449A compressor — 3.6 kW cooling, 1.60 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.

catalogR449A
Compressor · NA

Copeland RST80C1E-PFZ (R448A hermetic recip, 50 Hz, MT)

R448A compressor — 3.1 kW cooling, 1.29 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.

catalogR448A
Compressor · EU, APAC

Copeland RST80C1E-PFZ (R449A hermetic recip, 50 Hz, MT)

R449A compressor — 3.1 kW cooling, 1.29 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.

catalogR449A
Compressor · EU, APAC

Copeland RST84C2U-CFV (R454C hermetic recip, 60 Hz, EM)

R454C compressor — 3.6 kW cooling, 1.88 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.

catalogR454C
Compressor · NA

Copeland RST97C1E-PFV (R404A hermetic recip, 60 Hz, EM)

R404A compressor — 3.7 kW cooling, 1.89 kW input, COP 1.96 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Copeland RST97C1E-PFV (R448A hermetic recip, 60 Hz, MT)

R448A compressor — 4.0 kW cooling, 1.77 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point.

catalogR448A
Compressor · NA

Copeland RST97C1E-PFV (R449A hermetic recip, 60 Hz, MT)

R449A compressor — 4.0 kW cooling, 1.77 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point.

catalogR449A
Compressor · NA

Copeland RST97C1E-PFZ (R448A hermetic recip, 50 Hz, MT)

R448A compressor — 3.2 kW cooling, 1.38 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.

catalogR448A
Compressor · EU, APAC
‹ Previous1…9091929394…427Next ›