Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 3,457–3,474 of 3,474

NameCompanyCategoryCapacityMarketsOpen in the builder
Baltimore Aircoil PFI-2418N-3D4DS-P2 closed-circuit cooler (509 tons, 2.2 MW) — modelled Example modelled from published data
BAC's PFI-2418N-3D4DS-P2 — a PFi closed-circuit cooler, 509 nominal tons (2239 kW): rated to cool 1533 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 125.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1679–2799 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-3D4DS-Q2 closed-circuit cooler (535 tons, 2.4 MW) — modelled Example modelled from published data
BAC's PFI-2418N-3D4DS-Q2 — a PFi closed-circuit cooler, 535 nominal tons (2353 kW): rated to cool 1611 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 134.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1765–2941 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-3D4ES-M2 closed-circuit cooler (463 tons, 2.0 MW) — modelled Example modelled from published data
BAC's PFI-2418N-3D4ES-M2 — a PFi closed-circuit cooler, 463 nominal tons (2037 kW): rated to cool 1395 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 98.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1528–2547 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-3D4ES-R2 closed-circuit cooler (592 tons, 2.6 MW) — modelled Example modelled from published data
BAC's PFI-2418N-3D4ES-R2 — a PFi closed-circuit cooler, 592 nominal tons (2603 kW): rated to cool 1782 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 138.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1952–3253 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D1ES-O2 closed-circuit cooler (541 tons, 2.4 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D1ES-O2 — a PFi closed-circuit cooler, 541 nominal tons (2379 kW): rated to cool 1629 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 117.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1784–2974 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D2ES-Q2 closed-circuit cooler (616 tons, 2.7 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D2ES-Q2 — a PFi closed-circuit cooler, 616 nominal tons (2708 kW): rated to cool 1854 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 133.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2031–3385 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D2ES-R2 closed-circuit cooler (641 tons, 2.8 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D2ES-R2 — a PFi closed-circuit cooler, 641 nominal tons (2817 kW): rated to cool 1929 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 140.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2113–3522 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D3DS-P2 closed-circuit cooler (553 tons, 2.4 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D3DS-P2 — a PFi closed-circuit cooler, 553 nominal tons (2432 kW): rated to cool 1665 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 122.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1824–3040 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D3ES-P2 closed-circuit cooler (592 tons, 2.6 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D3ES-P2 — a PFi closed-circuit cooler, 592 nominal tons (2603 kW): rated to cool 1782 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 118.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1952–3253 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D3ES-Q2 closed-circuit cooler (623 tons, 2.7 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D3ES-Q2 — a PFi closed-circuit cooler, 623 nominal tons (2738 kW): rated to cool 1875 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 127.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2054–3423 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D4DS-M2 closed-circuit cooler (475 tons, 2.1 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D4DS-M2 — a PFi closed-circuit cooler, 475 nominal tons (2090 kW): rated to cool 1431 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 95.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1567–2612 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D4DS-O2 closed-circuit cooler (527 tons, 2.3 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D4DS-O2 — a PFi closed-circuit cooler, 527 nominal tons (2318 kW): rated to cool 1587 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 108.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1738–2897 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D4DS-P2 closed-circuit cooler (569 tons, 2.5 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D4DS-P2 — a PFi closed-circuit cooler, 569 nominal tons (2502 kW): rated to cool 1713 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 118.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1876–3127 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D4ES-Q2 closed-circuit cooler (637 tons, 2.8 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D4ES-Q2 — a PFi closed-circuit cooler, 637 nominal tons (2800 kW): rated to cool 1917 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 123.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2100–3500 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-4D4ES-R2 closed-circuit cooler (666 tons, 2.9 MW) — modelled Example modelled from published data
BAC's PFI-2418N-4D4ES-R2 — a PFi closed-circuit cooler, 666 nominal tons (2927 kW): rated to cool 2004 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 131.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2195–3658 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-5D2ES-Q2 closed-circuit cooler (658 tons, 2.9 MW) — modelled Example modelled from published data
BAC's PFI-2418N-5D2ES-Q2 — a PFi closed-circuit cooler, 658 nominal tons (2892 kW): rated to cool 1980 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 127.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2169–3615 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-6D1ES-R2 closed-circuit cooler (719 tons, 3.2 MW) — modelled Example modelled from published data
BAC's PFI-2418N-6D1ES-R2 — a PFi closed-circuit cooler, 719 nominal tons (3159 kW): rated to cool 2163 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 135.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2369–3949 kWEUOpen in the builder
Baltimore Aircoil PFI-2418N-6D3ES-R2 closed-circuit cooler (703 tons, 3.1 MW) — modelled Example modelled from published data
BAC's PFI-2418N-6D3ES-R2 — a PFi closed-circuit cooler, 703 nominal tons (3089 kW): rated to cool 2115 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 123.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2317–3861 kWEUOpen in the builder
‹ Previous1…143144145

Publishing here

Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers