| Baltimore Aircoil PFI-2412N-3D1DS-P2 closed-circuit cooler (313 tons, 1.4 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D1DS-P2 — a PFi closed-circuit cooler, 313 nominal tons (1376 kW): rated to cool 942 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 105.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1032–1720 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D2DS-K2 closed-circuit cooler (245 tons, 1.1 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D2DS-K2 — a PFi closed-circuit cooler, 245 nominal tons (1078 kW): rated to cool 738 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 65.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 808–1347 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D2DS-L2 closed-circuit cooler (265 tons, 1.2 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D2DS-L2 — a PFi closed-circuit cooler, 265 nominal tons (1165 kW): rated to cool 798 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 74.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 874–1457 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D2DS-N2 closed-circuit cooler (295 tons, 1.3 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D2DS-N2 — a PFi closed-circuit cooler, 295 nominal tons (1297 kW): rated to cool 888 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 87.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 973–1621 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D2DS-O2 closed-circuit cooler (306 tons, 1.3 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D2DS-O2 — a PFi closed-circuit cooler, 306 nominal tons (1345 kW): rated to cool 921 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 92.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1009–1681 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D2ES-L2 closed-circuit cooler (287 tons, 1.3 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D2ES-L2 — a PFi closed-circuit cooler, 287 nominal tons (1262 kW): rated to cool 864 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 71.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 946–1577 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D2ES-M2 closed-circuit cooler (304 tons, 1.3 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D2ES-M2 — a PFi closed-circuit cooler, 304 nominal tons (1336 kW): rated to cool 915 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 78.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1002–1670 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D3ES-N2 closed-circuit cooler (323 tons, 1.4 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D3ES-N2 — a PFi closed-circuit cooler, 323 nominal tons (1420 kW): rated to cool 972 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 81.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1065–1774 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D4DS-L2 closed-circuit cooler (276 tons, 1.2 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D4DS-L2 — a PFi closed-circuit cooler, 276 nominal tons (1214 kW): rated to cool 831 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 69.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 910–1517 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D4ES-M2 closed-circuit cooler (315 tons, 1.4 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D4ES-M2 — a PFi closed-circuit cooler, 315 nominal tons (1385 kW): rated to cool 948 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 73.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1038–1731 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D4ES-O2 closed-circuit cooler (345 tons, 1.5 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D4ES-O2 — a PFi closed-circuit cooler, 345 nominal tons (1516 kW): rated to cool 1038 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 83.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1137–1895 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-3D4ES-P2 closed-circuit cooler (368 tons, 1.6 MW) — modelled Example modelled from published data BAC's PFI-2412N-3D4ES-P2 — a PFi closed-circuit cooler, 368 nominal tons (1617 kW): rated to cool 1107 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 91.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1213–2021 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-4D2DS-M2 closed-circuit cooler (323 tons, 1.4 MW) — modelled Example modelled from published data BAC's PFI-2412N-4D2DS-M2 — a PFi closed-circuit cooler, 323 nominal tons (1420 kW): rated to cool 972 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 77.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1065–1774 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-4D2DS-N2 closed-circuit cooler (340 tons, 1.5 MW) — modelled Example modelled from published data BAC's PFI-2412N-4D2DS-N2 — a PFi closed-circuit cooler, 340 nominal tons (1494 kW): rated to cool 1023 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 83.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1121–1868 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-4D2ES-P2 closed-circuit cooler (406 tons, 1.8 MW) — modelled Example modelled from published data BAC's PFI-2412N-4D2ES-P2 — a PFi closed-circuit cooler, 406 nominal tons (1783 kW): rated to cool 1221 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 93.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1337–2229 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-4D3DS-P2 closed-circuit cooler (388 tons, 1.7 MW) — modelled Example modelled from published data BAC's PFI-2412N-4D3DS-P2 — a PFi closed-circuit cooler, 388 nominal tons (1704 kW): rated to cool 1167 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 91.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1278–2130 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-4D3ES-M2 closed-circuit cooler (351 tons, 1.5 MW) — modelled Example modelled from published data BAC's PFI-2412N-4D3ES-M2 — a PFi closed-circuit cooler, 351 nominal tons (1542 kW): rated to cool 1056 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 72.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1157–1928 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-4D4ES-N2 closed-circuit cooler (375 tons, 1.6 MW) — modelled Example modelled from published data BAC's PFI-2412N-4D4ES-N2 — a PFi closed-circuit cooler, 375 nominal tons (1647 kW): rated to cool 1128 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 75.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1236–2059 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-5D1DS-O2 closed-circuit cooler (375 tons, 1.6 MW) — modelled Example modelled from published data BAC's PFI-2412N-5D1DS-O2 — a PFi closed-circuit cooler, 375 nominal tons (1647 kW): rated to cool 1128 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 87.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1236–2059 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-5D2ES-N2 closed-circuit cooler (396 tons, 1.7 MW) — modelled Example modelled from published data BAC's PFI-2412N-5D2ES-N2 — a PFi closed-circuit cooler, 396 nominal tons (1739 kW): rated to cool 1191 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 77.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1305–2174 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-5D4DS-O2 closed-circuit cooler (394 tons, 1.7 MW) — modelled Example modelled from published data BAC's PFI-2412N-5D4DS-O2 — a PFi closed-circuit cooler, 394 nominal tons (1731 kW): rated to cool 1185 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 77.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1298–2163 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-5D4ES-O2 closed-circuit cooler (418 tons, 1.8 MW) — modelled Example modelled from published data BAC's PFI-2412N-5D4ES-O2 — a PFi closed-circuit cooler, 418 nominal tons (1836 kW): rated to cool 1257 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 75.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1377–2295 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-5D4ES-P2 closed-circuit cooler (446 tons, 2.0 MW) — modelled Example modelled from published data BAC's PFI-2412N-5D4ES-P2 — a PFi closed-circuit cooler, 446 nominal tons (1958 kW): rated to cool 1341 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 82.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1469–2448 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2412N-6D1DS-M2 closed-circuit cooler (369 tons, 1.6 MW) — modelled Example modelled from published data BAC's PFI-2412N-6D1DS-M2 — a PFi closed-circuit cooler, 369 nominal tons (1621 kW): rated to cool 1110 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 74.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1216–2026 kW | EU | Open in the builder |