Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 3,385–3,408 of 3,474

NameCompanyCategoryCapacityMarketsOpen in the builder
Baltimore Aircoil PFI-2012N-3D2ES-M2 closed-circuit cooler (256 tons, 1.1 MW) — modelled Example modelled from published data
BAC's PFI-2012N-3D2ES-M2 — a PFi closed-circuit cooler, 256 nominal tons (1126 kW): rated to cool 771 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 67.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection845–1408 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-3D2ES-O2 closed-circuit cooler (278 tons, 1.2 MW) — modelled Example modelled from published data
BAC's PFI-2012N-3D2ES-O2 — a PFi closed-circuit cooler, 278 nominal tons (1222 kW): rated to cool 837 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 77.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection917–1528 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-3D3DS-N2 closed-circuit cooler (259 tons, 1.1 MW) — modelled Example modelled from published data
BAC's PFI-2012N-3D3DS-N2 — a PFi closed-circuit cooler, 259 nominal tons (1139 kW): rated to cool 780 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 73.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection854–1424 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-3D4DS-L2 closed-circuit cooler (235 tons, 1.0 MW) — modelled Example modelled from published data
BAC's PFI-2012N-3D4DS-L2 — a PFi closed-circuit cooler, 235 nominal tons (1034 kW): rated to cool 708 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 60.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection776–1293 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-3D4DS-M2 closed-circuit cooler (251 tons, 1.1 MW) — modelled Example modelled from published data
BAC's PFI-2012N-3D4DS-M2 — a PFi closed-circuit cooler, 251 nominal tons (1104 kW): rated to cool 756 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 65.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection828–1380 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-3D4ES-O2 closed-circuit cooler (293 tons, 1.3 MW) — modelled Example modelled from published data
BAC's PFI-2012N-3D4ES-O2 — a PFi closed-circuit cooler, 293 nominal tons (1288 kW): rated to cool 882 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 72.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection966–1610 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-4D1DS-J2 closed-circuit cooler (216 tons, 951 kW) — modelled Example modelled from published data
BAC's PFI-2012N-4D1DS-J2 — a PFi closed-circuit cooler, 216 nominal tons (951 kW): rated to cool 651 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 50.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection713–1188 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-4D1DS-M2 closed-circuit cooler (266 tons, 1.2 MW) — modelled Example modelled from published data
BAC's PFI-2012N-4D1DS-M2 — a PFi closed-circuit cooler, 266 nominal tons (1170 kW): rated to cool 801 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 69.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection877–1462 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-4D1ES-J2 closed-circuit cooler (235 tons, 1.0 MW) — modelled Example modelled from published data
BAC's PFI-2012N-4D1ES-J2 — a PFi closed-circuit cooler, 235 nominal tons (1034 kW): rated to cool 708 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 49.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection776–1293 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-4D1ES-M2 closed-circuit cooler (289 tons, 1.3 MW) — modelled Example modelled from published data
BAC's PFI-2012N-4D1ES-M2 — a PFi closed-circuit cooler, 289 nominal tons (1271 kW): rated to cool 870 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 67.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection953–1588 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-4D2ES-N2 closed-circuit cooler (310 tons, 1.4 MW) — modelled Example modelled from published data
BAC's PFI-2012N-4D2ES-N2 — a PFi closed-circuit cooler, 310 nominal tons (1363 kW): rated to cool 933 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 69.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1022–1703 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-4D3ES-L2 closed-circuit cooler (283 tons, 1.2 MW) — modelled Example modelled from published data
BAC's PFI-2012N-4D3ES-L2 — a PFi closed-circuit cooler, 283 nominal tons (1244 kW): rated to cool 852 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 57.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection933–1555 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-4D3ES-N2 closed-circuit cooler (319 tons, 1.4 MW) — modelled Example modelled from published data
BAC's PFI-2012N-4D3ES-N2 — a PFi closed-circuit cooler, 319 nominal tons (1402 kW): rated to cool 960 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 67.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1052–1753 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-4D4ES-O2 closed-circuit cooler (335 tons, 1.5 MW) — modelled Example modelled from published data
BAC's PFI-2012N-4D4ES-O2 — a PFi closed-circuit cooler, 335 nominal tons (1472 kW): rated to cool 1008 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 68.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1104–1840 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-5D2DS-M2 closed-circuit cooler (298 tons, 1.3 MW) — modelled Example modelled from published data
BAC's PFI-2012N-5D2DS-M2 — a PFi closed-circuit cooler, 298 nominal tons (1310 kW): rated to cool 897 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 64.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection983–1638 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-5D2DS-N2 closed-circuit cooler (314 tons, 1.4 MW) — modelled Example modelled from published data
BAC's PFI-2012N-5D2DS-N2 — a PFi closed-circuit cooler, 314 nominal tons (1380 kW): rated to cool 945 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 68.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1035–1725 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-6D1ES-M2 closed-circuit cooler (337 tons, 1.5 MW) — modelled Example modelled from published data
BAC's PFI-2012N-6D1ES-M2 — a PFi closed-circuit cooler, 337 nominal tons (1481 kW): rated to cool 1014 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 62.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1111–1851 kWEUOpen in the builder
Baltimore Aircoil PFI-2012N-6D1ES-O2 closed-circuit cooler (370 tons, 1.6 MW) — modelled Example modelled from published data
BAC's PFI-2012N-6D1ES-O2 — a PFi closed-circuit cooler, 370 nominal tons (1625 kW): rated to cool 1113 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 71.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1219–2032 kWEUOpen in the builder
Baltimore Aircoil PFI-2412N-2D4DS-K2 closed-circuit cooler (198 tons, 872 kW) — modelled Example modelled from published data
BAC's PFI-2412N-2D4DS-K2 — a PFi closed-circuit cooler, 198 nominal tons (872 kW): rated to cool 597 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 65.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection654–1090 kWEUOpen in the builder
Baltimore Aircoil PFI-2412N-2D4ES-M2 closed-circuit cooler (238 tons, 1.0 MW) — modelled Example modelled from published data
BAC's PFI-2412N-2D4ES-M2 — a PFi closed-circuit cooler, 238 nominal tons (1047 kW): rated to cool 717 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 78.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection785–1309 kWEUOpen in the builder
Baltimore Aircoil PFI-2412N-2D4ES-N2 closed-circuit cooler (249 tons, 1.1 MW) — modelled Example modelled from published data
BAC's PFI-2412N-2D4ES-N2 — a PFi closed-circuit cooler, 249 nominal tons (1095 kW): rated to cool 750 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 84.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection822–1369 kWEUOpen in the builder
Baltimore Aircoil PFI-2412N-2D4ES-O2 closed-circuit cooler (259 tons, 1.1 MW) — modelled Example modelled from published data
BAC's PFI-2412N-2D4ES-O2 — a PFi closed-circuit cooler, 259 nominal tons (1139 kW): rated to cool 780 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 89.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection854–1424 kWEUOpen in the builder
Baltimore Aircoil PFI-2412N-3D1DS-M2 closed-circuit cooler (271 tons, 1.2 MW) — modelled Example modelled from published data
BAC's PFI-2412N-3D1DS-M2 — a PFi closed-circuit cooler, 271 nominal tons (1192 kW): rated to cool 816 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 84.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection894–1490 kWEUOpen in the builder
Baltimore Aircoil PFI-2412N-3D1DS-N2 closed-circuit cooler (284 tons, 1.2 MW) — modelled Example modelled from published data
BAC's PFI-2412N-3D1DS-N2 — a PFi closed-circuit cooler, 284 nominal tons (1249 kW): rated to cool 855 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 90.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection937–1561 kWEUOpen in the builder
‹ Previous1…140141142143144145Next ›

Publishing here

Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers