Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 3,361–3,384 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| Baltimore Aircoil PFI-1236N-3D4DS-Q2 closed-circuit cooler (535 tons, 2.4 MW) — modelled Example modelled from published data BAC's PFI-1236N-3D4DS-Q2 — a PFi closed-circuit cooler, 535 nominal tons (2353 kW): rated to cool 1611 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 134.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1765–2941 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-3D4ES-M2 closed-circuit cooler (463 tons, 2.0 MW) — modelled Example modelled from published data BAC's PFI-1236N-3D4ES-M2 — a PFi closed-circuit cooler, 463 nominal tons (2037 kW): rated to cool 1395 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 98.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1528–2547 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-3D4ES-R2 closed-circuit cooler (592 tons, 2.6 MW) — modelled Example modelled from published data BAC's PFI-1236N-3D4ES-R2 — a PFi closed-circuit cooler, 592 nominal tons (2603 kW): rated to cool 1782 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 138.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1952–3253 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D1ES-O2 closed-circuit cooler (541 tons, 2.4 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D1ES-O2 — a PFi closed-circuit cooler, 541 nominal tons (2379 kW): rated to cool 1629 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 117.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1784–2974 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D2ES-Q2 closed-circuit cooler (616 tons, 2.7 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D2ES-Q2 — a PFi closed-circuit cooler, 616 nominal tons (2708 kW): rated to cool 1854 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 133.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2031–3385 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D2ES-R2 closed-circuit cooler (641 tons, 2.8 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D2ES-R2 — a PFi closed-circuit cooler, 641 nominal tons (2817 kW): rated to cool 1929 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 140.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2113–3522 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D3DS-P2 closed-circuit cooler (553 tons, 2.4 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D3DS-P2 — a PFi closed-circuit cooler, 553 nominal tons (2432 kW): rated to cool 1665 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 122.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1824–3040 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D3ES-P2 closed-circuit cooler (592 tons, 2.6 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D3ES-P2 — a PFi closed-circuit cooler, 592 nominal tons (2603 kW): rated to cool 1782 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 118.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1952–3253 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D3ES-Q2 closed-circuit cooler (623 tons, 2.7 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D3ES-Q2 — a PFi closed-circuit cooler, 623 nominal tons (2738 kW): rated to cool 1875 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 127.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2054–3423 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D4DS-M2 closed-circuit cooler (475 tons, 2.1 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D4DS-M2 — a PFi closed-circuit cooler, 475 nominal tons (2090 kW): rated to cool 1431 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 95.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1567–2612 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D4DS-P2 closed-circuit cooler (569 tons, 2.5 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D4DS-P2 — a PFi closed-circuit cooler, 569 nominal tons (2502 kW): rated to cool 1713 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 118.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1876–3127 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D4ES-Q2 closed-circuit cooler (637 tons, 2.8 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D4ES-Q2 — a PFi closed-circuit cooler, 637 nominal tons (2800 kW): rated to cool 1917 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 123.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2100–3500 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-4D4ES-R2 closed-circuit cooler (666 tons, 2.9 MW) — modelled Example modelled from published data BAC's PFI-1236N-4D4ES-R2 — a PFi closed-circuit cooler, 666 nominal tons (2927 kW): rated to cool 2004 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 131.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2195–3658 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-5D2ES-Q2 closed-circuit cooler (658 tons, 2.9 MW) — modelled Example modelled from published data BAC's PFI-1236N-5D2ES-Q2 — a PFi closed-circuit cooler, 658 nominal tons (2892 kW): rated to cool 1980 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 127.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2169–3615 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-6D1ES-R2 closed-circuit cooler (719 tons, 3.2 MW) — modelled Example modelled from published data BAC's PFI-1236N-6D1ES-R2 — a PFi closed-circuit cooler, 719 nominal tons (3159 kW): rated to cool 2163 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 135.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2369–3949 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1236N-6D3ES-R2 closed-circuit cooler (703 tons, 3.1 MW) — modelled Example modelled from published data BAC's PFI-1236N-6D3ES-R2 — a PFi closed-circuit cooler, 703 nominal tons (3089 kW): rated to cool 2115 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 123.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2317–3861 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2012N-2D2DS-J2 closed-circuit cooler (150 tons, 657 kW) — modelled Example modelled from published data BAC's PFI-2012N-2D2DS-J2 — a PFi closed-circuit cooler, 150 nominal tons (657 kW): rated to cool 450 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 54.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 493–822 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2012N-2D2ES-L2 closed-circuit cooler (178 tons, 784 kW) — modelled Example modelled from published data BAC's PFI-2012N-2D2ES-L2 — a PFi closed-circuit cooler, 178 nominal tons (784 kW): rated to cool 537 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 64.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 588–980 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2012N-2D4ES-K2 closed-circuit cooler (175 tons, 771 kW) — modelled Example modelled from published data BAC's PFI-2012N-2D4ES-K2 — a PFi closed-circuit cooler, 175 nominal tons (771 kW): rated to cool 528 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 54.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 578–964 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2012N-2D4ES-N2 closed-circuit cooler (210 tons, 924 kW) — modelled Example modelled from published data BAC's PFI-2012N-2D4ES-N2 — a PFi closed-circuit cooler, 210 nominal tons (924 kW): rated to cool 633 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 73.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 693–1156 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2012N-3D1DS-L2 closed-circuit cooler (216 tons, 951 kW) — modelled Example modelled from published data BAC's PFI-2012N-3D1DS-L2 — a PFi closed-circuit cooler, 216 nominal tons (951 kW): rated to cool 651 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 66.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 713–1188 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2012N-3D2DS-K2 closed-circuit cooler (206 tons, 907 kW) — modelled Example modelled from published data BAC's PFI-2012N-3D2DS-K2 — a PFi closed-circuit cooler, 206 nominal tons (907 kW): rated to cool 621 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 56.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 680–1134 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2012N-3D2DS-M2 closed-circuit cooler (237 tons, 1.0 MW) — modelled Example modelled from published data BAC's PFI-2012N-3D2DS-M2 — a PFi closed-circuit cooler, 237 nominal tons (1043 kW): rated to cool 714 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 70.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 782–1303 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-2012N-3D2ES-L2 closed-circuit cooler (242 tons, 1.1 MW) — modelled Example modelled from published data BAC's PFI-2012N-3D2ES-L2 — a PFi closed-circuit cooler, 242 nominal tons (1065 kW): rated to cool 729 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 61.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 799–1331 kW | EU | Open in the builder |
Publishing here
Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers