677 listing(s) in HVAC Builder's catalog from Baltimore Aircoil's published data and 6 system(s) modelled on it, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Baltimore Aircoil has not claimed it.

Are you Baltimore Aircoil?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Systems modelled on Baltimore Aircoil's published data

Built in this model on the maker's own published data — not verified by Baltimore Aircoil. Each page names the document it was read from and what the model was held to.

Baltimore Aircoil VT0-12-E cooling tower (12 tons, 53 kW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series V engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil FXT-0709B-J cooling tower (130 tons, 571 kW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, FXT engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil Series 1500 S15E-1285-09LN cooling tower (253 tons, 1.1 MW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series 1500 engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil VT1-600-P cooling tower (600 tons, 2.6 MW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series V engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil Series 3000 S3E-1222-06N cooling tower (471 tons, 2.1 MW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series 3000 engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil VFL-036-32M closed-circuit cooler (56 tons, 246 kW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series V closed circuit engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)

Listings

All kindsCooling tower 677
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 385–408 of 677

Baltimore Aircoil Series V closed circuit VF1-009-12G closed-circuit cooler

Closed-circuit cooler — 22 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 2.7 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-009-22F closed-circuit cooler

Closed-circuit cooler — 26 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 2.3 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-009-22G closed-circuit cooler

Closed-circuit cooler — 31 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 2.6 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-009-32G closed-circuit cooler

Closed-circuit cooler — 35 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 2.6 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-009-42G closed-circuit cooler

Closed-circuit cooler — 39 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 2.6 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-12F closed-circuit cooler

Closed-circuit cooler — 39 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 3.8 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-12G closed-circuit cooler

Closed-circuit cooler — 48 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 4.4 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-12H closed-circuit cooler

Closed-circuit cooler — 61 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 5.2 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-22H closed-circuit cooler

Closed-circuit cooler — 74 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 5.1 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-22J closed-circuit cooler

Closed-circuit cooler — 88 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 5.8 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-32G closed-circuit cooler

Closed-circuit cooler — 70 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 4.2 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-32H closed-circuit cooler

Closed-circuit cooler — 83 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 5.0 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-32J closed-circuit cooler

Closed-circuit cooler — 96 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 5.7 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-42H closed-circuit cooler

Closed-circuit cooler — 92 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 5.0 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-018-42J closed-circuit cooler

Closed-circuit cooler — 105 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 5.7 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-027-22H closed-circuit cooler

Closed-circuit cooler — 105 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 6.6 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-027-22J closed-circuit cooler

Closed-circuit cooler — 123 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 7.6 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-027-22K closed-circuit cooler

Closed-circuit cooler — 140 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 8.4 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-027-32H closed-circuit cooler

Closed-circuit cooler — 114 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 6.6 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-027-32J closed-circuit cooler

Closed-circuit cooler — 136 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 7.5 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-027-32K closed-circuit cooler

Closed-circuit cooler — 153 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 8.3 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-027-42H closed-circuit cooler

Closed-circuit cooler — 123 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 6.5 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-027-42J closed-circuit cooler

Closed-circuit cooler — 145 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 7.4 m³/s of air.

catalog
Cooling tower

Baltimore Aircoil Series V closed circuit VF1-027-42K closed-circuit cooler

Closed-circuit cooler — 162 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 8.2 m³/s of air.

catalog
Cooling tower