677 listing(s) in HVAC Builder's catalog from Baltimore Aircoil's published data and 6 system(s) modelled on it, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Baltimore Aircoil has not claimed it.
Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Built in this model on the maker's own published data — not verified by Baltimore Aircoil. Each page names the document it was read from and what the model was held to.
| Baltimore Aircoil VT0-12-E cooling tower (12 tons, 53 kW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series V engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil FXT-0709B-J cooling tower (130 tons, 571 kW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, FXT engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil Series 1500 S15E-1285-09LN cooling tower (253 tons, 1.1 MW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series 1500 engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil VT1-600-P cooling tower (600 tons, 2.6 MW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series V engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil Series 3000 S3E-1222-06N cooling tower (471 tons, 2.1 MW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series 3000 engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil VFL-036-32M closed-circuit cooler (56 tons, 246 kW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series V closed circuit engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
Showing 601–624 of 677
Cooling tower — 4600 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 89.9 m³/s of air.
Cooling tower — 4627 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 100.9 m³/s of air.
Cooling tower — 4876 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 99.0 m³/s of air.
Cooling tower — 4982 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 107.6 m³/s of air.
Cooling tower — 5231 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 105.9 m³/s of air.
Cooling tower — 5521 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 112.7 m³/s of air.
Cooling tower — 1385 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 31.1 m³/s of air.
Cooling tower — 1437 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 30.5 m³/s of air.
Cooling tower — 1525 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 34.1 m³/s of air.
Cooling tower — 1533 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 30.0 m³/s of air.
Cooling tower — 1542 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.6 m³/s of air.
Cooling tower — 1625 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.0 m³/s of air.
Cooling tower — 1661 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 35.9 m³/s of air.
Cooling tower — 1744 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 35.3 m³/s of air.
Cooling tower — 1840 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 37.6 m³/s of air.
Cooling tower — 1888 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 48.6 m³/s of air.
Cooling tower — 1994 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 51.7 m³/s of air.
Cooling tower — 2121 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 48.3 m³/s of air.
Cooling tower — 2252 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 51.3 m³/s of air.
Cooling tower — 2256 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 48.0 m³/s of air.
Cooling tower — 2335 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 47.7 m³/s of air.
Cooling tower — 2383 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 51.0 m³/s of air.
Cooling tower — 2440 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 50.7 m³/s of air.
Cooling tower — 2454 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 56.5 m³/s of air.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.