Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Systems modelled on Baltimore Aircoil's published data

Built in this model on the maker's own published data — not verified by Baltimore Aircoil. Each page names the document it was read from and what the model was held to.

Baltimore Aircoil VT0-12-E cooling tower (12 tons, 53 kW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series V engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil VCL-016 evaporative condenser (69 kW rejection) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series V evaporative condenser engineering data — the VCL-016 row (Base Heat Rejection, airflow, fan motor) on the sheet's own stated basis: model number in R-22 tons at a 105 °F condensing temperature, 40 °F suction and a 78 °F entering wet bulb (docs/bac-source.json → condensers)
Baltimore Aircoil VFL-036-32M closed-circuit cooler (56 tons, 246 kW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series V closed circuit engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil FXT-0709B-J cooling tower (130 tons, 571 kW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, FXT engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil VT1-600-P cooling tower (600 tons, 2.6 MW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series V engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil Series 1500 S15E-1285-09LN cooling tower (253 tons, 1.1 MW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series 1500 engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)
Baltimore Aircoil Series 3000 S3E-1222-06N cooling tower (471 tons, 2.1 MW) — modelledBaltimore Aircoil Product & Application Handbook volume VI, Series 3000 engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json)

Every listed unit as a system

1115 more of Baltimore Aircoil's units open as systems of their own — each the listing's rating, airflow and fan, drawn as the maker builds it, derived from its catalog row rather than written by hand — in the systems directory and in the builder's systems picker under Baltimore Aircoil, by series:

Listings

All kindsCooling tower 1121Coil 705
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 1729–1752 of 1826

Baltimore Aircoil Vertex VRC VRC-0467B-1218N-HB evaporative condenser

Evaporative condenser — 2829 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 56.6 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0469B-1212N-NA evaporative condenser

Evaporative condenser — 2848 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 43.3 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0470B-1024N-JA evaporative condenser

Evaporative condenser — 2852 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 64.7 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0476B-1018N-HB evaporative condenser

Evaporative condenser — 2886 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 41.3 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0481B-1018N-JB evaporative condenser

Evaporative condenser — 2920 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 58.3 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0484B-1024N-HA evaporative condenser

Evaporative condenser — 2930 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 52.3 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0486B-1224N-HA evaporative condenser

Evaporative condenser — 2947 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 56.4 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0489B-1218N-KA evaporative condenser

Evaporative condenser — 2964 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 51.8 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0502B-1018N-KA evaporative condenser

Evaporative condenser — 3046 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 44.5 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0510B-1218N-HB evaporative condenser

Evaporative condenser — 3093 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 54.3 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0511B-1018N-HB evaporative condenser

Evaporative condenser — 3102 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 42.3 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0516B-1218N-JB evaporative condenser

Evaporative condenser — 3126 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 65.7 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0526B-1018N-JB evaporative condenser

Evaporative condenser — 3191 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 47.9 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0533B-1024N-JA evaporative condenser

Evaporative condenser — 3231 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 59.8 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0533B-1218N-KA evaporative condenser

Evaporative condenser — 3231 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 50.4 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0535B-1224N-JA evaporative condenser

Evaporative condenser — 3248 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 64.6 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0538B-1024N-HB evaporative condenser

Evaporative condenser — 3264 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 78.7 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0541B-1224N-HA evaporative condenser

Evaporative condenser — 3283 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 56.4 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0553B-1018N-LA evaporative condenser

Evaporative condenser — 3356 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 50.9 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0555B-1218N-HB evaporative condenser

Evaporative condenser — 3369 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 51.3 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0564B-1218N-JB evaporative condenser

Evaporative condenser — 3419 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 63.0 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0565B-1018N-JB evaporative condenser

Evaporative condenser — 3430 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 49.1 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0571B-1024N-KA evaporative condenser

Evaporative condenser — 3464 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 65.9 m³/s of air.

catalog
Coil

Baltimore Aircoil Vertex VRC VRC-0574B-1224N-KA evaporative condenser

Evaporative condenser — 3481 kW rejected at 40.6 °C condensing and a 25.6 °C wet bulb, 71.1 m³/s of air.

catalog
Coil
‹ Previous1717273747577Next ›

Worked cases that run Baltimore Aircoil machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.