Copeland Unclaimed

5,452 listings in HVAC Builder's catalog from Copeland's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Copeland has not claimed it.

Compressor maps by refrigerant: R407C 718, R448A 540, R407F 479, R407A 474, R404A 441, R449A 361, R410A 356, R134a 310, R22 277, R507 247, R454C 234, R455A 219, R513A 218, R454A 214, R290 145, R454B 106, R32 44, R450A 32, R1234yf 22, R452A 14, R245fa 1.

Copeland compressor ranges

Each range on a page of its own: every model code with its refrigerants, frequencies and ratings, and every model a page.

Are you Copeland?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Components

Showing 25–48 of 5,452

NameTypeRatingMarketsOpen in the builder
Copeland 3DKHR15ME-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsR407A compressor — 49.6 kW cooling, 16.03 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland 3DKHS11ML-TFD (R407F Discus recip, 60 Hz, MD) CatalogCompressorsR407F compressor — 20.2 kW cooling, 7.51 kW input, COP 2.69 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3DPHR12ME-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsR407A compressor — 42.5 kW cooling, 13.01 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland 3DS3F46K0-ES8 (R448A Discus recip, 60 Hz, LT) CatalogCompressorsR448A compressor — 8.7 kW cooling, 6.70 kW input, COP 1.29 at -35/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3DSDF46KE-TFC (R407C Discus recip, 60 Hz, LD) CatalogCompressorsR407C compressor — 9.3 kW cooling, 5.78 kW input, COP 1.61 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3DSDR17ME-TFD (R407A Discus recip, 50 Hz, MD) CatalogCompressorsR407A compressor — 23.0 kW cooling, 8.45 kW input, COP 2.72 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland 3DSDS12ME-TFC (R407C Discus recip, 60 Hz, MD) CatalogCompressorsR407C compressor — 22.0 kW cooling, 8.45 kW input, COP 2.60 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3DT4S12ME-TFD (R448A Discus recip, 60 Hz, MD) CatalogCompressorsR448A compressor — 24.2 kW cooling, 8.93 kW input, COP 2.71 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3DTHR17ME-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsR407A compressor — 56.3 kW cooling, 17.90 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland 3DTHS12ML-TFD (R407F Discus recip, 60 Hz, MD) CatalogCompressorsR407F compressor — 23.7 kW cooling, 8.90 kW input, COP 2.66 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3PA3F29KE-TFD (R410A Discus recip, 60 Hz, LD) CatalogCompressorsR410A compressor — 8.7 kW cooling, 5.22 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3PADF29KE-TFD (R410A Discus recip, 60 Hz, LD) CatalogCompressorsR410A compressor — 8.7 kW cooling, 5.22 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3PADR10ME-TFD (R410A Discus recip, 60 Hz, MD) CatalogCompressorsR410A compressor — 27.1 kW cooling, 9.62 kW input, COP 2.81 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3YA3F21KL-TFC (R454A Discus recip, 60 Hz, LD) CatalogCompressorsR454A compressor — 7.1 kW cooling, 4.27 kW input, COP 1.65 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3YADR99KE-TFC (R454A Discus recip, 60 Hz, MD) CatalogCompressorsR454A compressor — 18.9 kW cooling, 7.01 kW input, COP 2.69 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3YB3R11ME-TFC (R454A Discus recip, 60 Hz, MD) CatalogCompressorsR454A compressor — 22.3 kW cooling, 8.29 kW input, COP 2.68 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3YBDR11ME-TFC (R454A Discus recip, 60 Hz, MD) CatalogCompressorsR454A compressor — 22.3 kW cooling, 8.29 kW input, COP 2.68 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3YF3R14ME-TFC (R454A Discus recip, 60 Hz, MD) CatalogCompressorsR454A compressor — 26.5 kW cooling, 9.96 kW input, COP 2.66 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3YFDR14ME-TFC (R454A Discus recip, 60 Hz, MD) CatalogCompressorsR454A compressor — 26.5 kW cooling, 9.96 kW input, COP 2.66 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 3YFDS87KE-TFD (R454A Discus recip, 50 Hz, MD) CatalogCompressorsR454A compressor — 18.7 kW cooling, 7.13 kW input, COP 2.62 at -20/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland 3YS3R16ME-TFC (R454A Discus recip, 50 Hz, MD) CatalogCompressorsR454A compressor — 24.6 kW cooling, 9.25 kW input, COP 2.66 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland 4DA3F47KL-TSK (R407C Discus recip, 60 Hz, LD) CatalogCompressorsR407C compressor — 9.9 kW cooling, 6.17 kW input, COP 1.60 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 4DADF47KL-TSK (R407C Discus recip, 60 Hz, LD) CatalogCompressorsR407C compressor — 9.9 kW cooling, 6.17 kW input, COP 1.60 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 4DADR18ML-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsR448A compressor — 31.0 kW cooling, 10.85 kW input, COP 2.86 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1234…228Next ›

How the model reads against Copeland's data

Compressor maps converted from the vendor's own rating database5 452 maps (4 776 of the worldwide publication, 676 of the Asia and China publications listed for their region)every basis median within 3.1 % of the nomenclature; the vendor's polynomial substituted exactly, never refitted; each map's superheat and subcooling reference read off its own rating row (the ZW heat pumps at 5 K, the ZH/YH at 10 K, the Discus at 25 K, the small hermetics at a 40 °F return gas)
The compressor map's superheat/subcooling correction — AHRI-rated maps read at EN 12900 conditions99 R410A (13 models) + 22 R407C + 35 R134athe corrected map reads the guide's capacity at −0.1 % mean / 1.0 % RMS on R410A, flat across evaporating temperature, every model within ±1.6 %; R407C nominal +1.0 % / 1.8 % (with the subcooling measured from the bubble point, as AHRI 540 Appendix C reads it — +0.3 % when it was measured from the dew point, a difference inside the band either way); R134a +1.5 % / 1.8 %. The uncorrected polynomial reads +9 to +11 %. The R404A refrigeration scrolls, rated at a return gas rather than a superheat, read the guide's 20 °C return-gas tables at +0.7 % / 1.5 % from −15 to −5 °C (88 points) — there the correction is a one-per-cent matter either way. Not held: the heat-pump scrolls, for which the guide prints heating capacity — and one R407C row (ZRD72KCE) disagrees with its map by a quarter and is recorded as a catalogue fault
Drake Chillers PAC360D (30 HP, R407C and R404A), modelled — one air-cooled chiller on the catalog's maps of the compressor its sheet names, on both refrigerants it is sold on44 + the pinned cellthe pinned 45 °F row within −1.9 to +1.7 % on tons and −2.8 to 0 % on compressor power; every water row's ambient trend on both fluids, each cell against its row's 95 °F cell, at 1.2 % RMS on tons (worst 3.3) and 1.9 % on power (worst 4.7); and at 55 °F, the one leaving temperature both tables print, R404A's capacity over R407C's within −1.6 to −2.9 % of the sheet's ratio. Recorded, not held to the sheet: the sheet holds its evaporator at one approach whatever the duty ("selected upon requirements"), so one fixed conductance reads +6 to +11 % at 35 °F and −14 to −15 % at 65 °F; R404A's power over R407C's reads 4.9–8.7 % above the sheet's at 55 °F — the condenser model holds the refrigerant at its dew point, which credits R407C with half its 4.7 K glide, while the sheet's two tables are one condenser on the mean condensing temperature; the 0–25 °F R404A rows want glycol
KeepRite KEZ Generation D scroll condensing units, modelled — four frames on the catalog's maps of the Copeland scrolls the manual names, against its capacity tables on four refrigerants806 cells on 15 tables (KEZA009H8, KEZA050H8, KEZA150H8, KEZA150L8), four of them pinnedon the one condenser each, R404A within 0.5–1.1 % RMS (worst +3.4 %) and R407A, R407C and R448A within 1.3–3.7 % RMS (worst −6.9 and +6.7 %, both R448A), every table's mean within a point of the day's — a band no table read one ambient column or one suction row over meets; the 50 cells the manual shades for a 20 °F superheat limit read like the rest. What it tests is the four maps at their own rating basis more than the condenser: the tables are three significant figures with no power, and on three of the four frames the pinned airflow is not air the printed fans could move — through the stated coil it takes 1.9–4.1 times the air power they could give at the best static efficiency of a catalog axial fan of their size, so it stands for the conductance the tables ask for. The suction temperature reads as a dew point — taken as a mid-point the R448A tables read 10–11 % high. Across the manual's 18 cooler frames with a map the same reading runs 1.5–5.2 % RMS, KEZA061H8's R407C table apart (8–46 % under its map), and 10 of them ask a condenser their fans could not drive; the freezer tables mostly print more than their maps give near the ambient — three cannot be reached at any airflow, none is air its fans could move — and are recorded, not modelled

From the validation page; every row is held by a test.

Worked cases that run Copeland machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.