Catalog · Copeland
Copeland ARE reciprocating compressors
30 Copeland ARE compressor maps from the maker's published data — 21 model codes on R513A (16), R134a (7), R450A (7). Every model is a page of its own with its AHRI 540 / EN 12900 map sampled across the published envelope, and every one is selectable in the builder, which solves it with the catalog's own figures.
| Model code | Listing | Refrigerant | Evaporating range °C | kW at 7.2 / 54.4 °C |
|---|
| ARE13C4E-IAA | Copeland ARE13C4E-IAA (R134A hermetic recip, 60 Hz, HT) | R134a | -18 … 13 | 0.4 |
| Copeland ARE13C4E-IAA (R450A hermetic recip, 60 Hz, HT) | R450A | -18 … 13 | 0.4 |
| Copeland ARE13C4E-IAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 0.4 |
| ARE17C4E-IAA | Copeland ARE17C4E-IAA (R134A hermetic recip, 60 Hz, HT) | R134a | -18 … 13 | 0.5 |
| Copeland ARE17C4E-IAA (R450A hermetic recip, 60 Hz, HT) | R450A | -18 … 13 | 0.5 |
| Copeland ARE17C4E-IAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 0.5 |
| ARE25C4E-IAA | Copeland ARE25C4E-IAA (R134A hermetic recip, 60 Hz, HT) | R134a | -18 … 13 | 0.7 |
| Copeland ARE25C4E-IAA (R450A hermetic recip, 60 Hz, HT) | R450A | -18 … 13 | 0.6 |
| ARE25C4E-IAZ | Copeland ARE25C4E-IAZ (R513A hermetic recip, 50 Hz, HT) | R513A | -18 … 13 | 0.6 |
| ARE25C5E-CAA | Copeland ARE25C5E-CAA (R134A hermetic recip, 60 Hz, HT) | R134a | -18 … 13 | 0.9 |
| Copeland ARE25C5E-CAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 0.9 |
| ARE29C4E-IAA | Copeland ARE29C4E-IAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 0.9 |
| ARE29C4E-IAI | Copeland ARE29C4E-IAI (R134A hermetic recip, 60 Hz, HT) | R134a | -18 … 13 | 0.8 |
| ARE29C4E-IAZ | Copeland ARE29C4E-IAZ (R513A hermetic recip, 50 Hz, HT) | R513A | -18 … 13 | 0.7 |
| ARE34C4E-IAA | Copeland ARE34C4E-IAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 1.0 |
| ARE34C4E-IAZ | Copeland ARE34C4E-IAZ (R513A hermetic recip, 50 Hz, HT) | R513A | -18 … 13 | 0.9 |
| ARE35C5E-CAA | Copeland ARE35C5E-CAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 1.1 |
| ARE35C5E-IAB | Copeland ARE35C5E-IAB (R513A hermetic recip, 50 Hz, HT) | R513A | -18 … 13 | 0.9 |
| ARE35C5E-IAI | Copeland ARE35C5E-IAI (R134A hermetic recip, 60 Hz, HT) | R134a | -18 … 13 | 1.0 |
| ARE40C4E-IAA | Copeland ARE40C4E-IAA (R450A hermetic recip, 60 Hz, HT) | R450A | -18 … 13 | 1.0 |
| Copeland ARE40C4E-IAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 1.2 |
| ARE42C5E-CAA | Copeland ARE42C5E-CAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 1.4 |
| ARE46C4E-IAA | Copeland ARE46C4E-IAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 1.4 |
| ARE48C5E-CAA | Copeland ARE48C5E-CAA (R450A hermetic recip, 60 Hz, HT) | R450A | -18 … 13 | 1.4 |
| Copeland ARE48C5E-CAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 1.4 |
| ARE48C5E-CAI | Copeland ARE48C5E-CAI (R134A hermetic recip, 60 Hz, HT) | R134a | -18 … 13 | 1.4 |
| ARE51C4E-CAA | Copeland ARE51C4E-CAA (R450A hermetic recip, 60 Hz, HT) | R450A | -18 … 13 | 1.3 |
| ARE51C4E-IAZ | Copeland ARE51C4E-IAZ (R450A hermetic recip, 50 Hz, HT) | R450A | -18 … 13 | 1.1 |
| Copeland ARE51C4E-IAZ (R513A hermetic recip, 50 Hz, HT) | R513A | -18 … 13 | 1.4 |
| ARE54C5E-CAA | Copeland ARE54C5E-CAA (R513A hermetic recip, 60 Hz, HT) | R513A | -18 … 13 | 1.6 |
The rating is the map read at the AHRI 540 air-conditioning point; a dash means the point lies outside the machine's own envelope (a refrigeration compressor is not rated there). The evaporating range is the published envelope's.
Open the builder and pick any of them from the catalog picker, or read one at your own conditions in the compressor-map lookup.
Other Copeland ranges: ZB (485) · ZF (406) · YF (254) · ZR (227) · ZS (215) · YB (213) · ZBD (202) · YS (190) · ZP (133) · YBD (123) · CR (91) · YFH (79) · ZW (74) · ZFH (70) · ASE (67) · CS (52) · every Copeland listing.