Tecumseh Unclaimed
1,891 listings in HVAC Builder's catalog from Tecumseh's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Tecumseh has not claimed it.
- Compressors — 1,891
Compressor maps by refrigerant: R404A 327, R452A 250, R448A 245, R449A 240, R134a 180, R455A 115, R290 111, R454C 106, R22 97, R513A 89, R407C 61, R1234yf 53, R600a 10, R410A 4, R407A 3.
Tecumseh compressor ranges
Each range on a page of its own: every model code with its refrigerants, frequencies and ratings, and every model a page.
- Tecumseh AJ — 523
- Tecumseh FH — 340
- Tecumseh AE — 248
- Tecumseh AG — 238
- Tecumseh AGB — 163
- Tecumseh AJK — 69
- Tecumseh AWS — 49
- Tecumseh TC — 27
- Tecumseh TCW — 26
- Tecumseh THB — 23
- Tecumseh AKA — 22
- Tecumseh AL — 18
- Tecumseh AWA — 17
- Tecumseh THG — 16
- Tecumseh AH — 12
- Tecumseh ALX — 12
- Tecumseh RGA — 12
- Tecumseh TA — 12
- Tecumseh HG — 11
- Tecumseh AHC — 6
- Tecumseh HGA — 6
- Tecumseh RG — 6
- Tecumseh AVA — 5
- Tecumseh AEX — 4
- Tecumseh AWR — 4
- Tecumseh VSG — 4
- Tecumseh CAJ — 3
- Tecumseh RKA — 3
- Tecumseh VS — 3
- Tecumseh TCX — 2
- Tecumseh VSC — 2
Are you Tecumseh?
Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Components
Showing 625–648 of 1,891
| Name | Type | Rating | Markets | Open in the builder |
|---|---|---|---|---|
| Tecumseh AGB4553ZTZ (R452A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | R452A compressor — 10.8 kW cooling, 4.90 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh AJ2440P-FZ3A (R454C hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R454C compressor — 0.41 kW cooling, 0.43 kW input, COP 0.95 at -30/50 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AJK513Z-GZ3C (R407C hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | R407C compressor — 2.9 kW cooling, 1.26 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh FH2511P-XC3A (R455A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R455A compressor — 1.6 kW cooling, 1.49 kW input, COP 1.08 at -30/50 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AE2420Z-AA1B (R404A hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | R404A compressor — 0.33 kW cooling, 0.33 kW input, COP 0.99 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AG2516Z-TZ1D (R449A hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | R449A compressor — 2.5 kW cooling, 2.22 kW input, COP 1.14 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AGB4553ZTZ (R452A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | R452A compressor — 13.0 kW cooling, 6.19 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh AJ2440P-FZ3A (R455A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R455A compressor — 0.44 kW cooling, 0.45 kW input, COP 0.96 at -30/50 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AJK513Z-GZ3C (R448A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | R448A compressor — 3.0 kW cooling, 1.34 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh FH2511P-XG1A (R404A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R404A compressor — 1.4 kW cooling, 1.43 kW input, COP 0.97 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AE2420Z-AA1B (R448A hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | R448A compressor — 0.45 kW cooling, 0.33 kW input, COP 1.35 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AG2516Z-TZ1D (R452A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R452A compressor — 1.4 kW cooling, 1.63 kW input, COP 0.88 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AGB4561ZKZ (R22 hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | R22 compressor — 12.9 kW cooling, 5.40 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh AJ2440Z-FZ3C (R404A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R404A compressor — 0.40 kW cooling, 0.49 kW input, COP 0.81 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AJK513Z-GZ3C (R449A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | R449A compressor — 3.0 kW cooling, 1.34 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh FH2511P-XG1A (R404A hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | R404A compressor — 1.5 kW cooling, 1.56 kW input, COP 0.99 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AE2420Z-AA1B (R449A hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | R449A compressor — 0.45 kW cooling, 0.33 kW input, COP 1.35 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AG2516Z-TZ1D (R452A hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | R452A compressor — 1.7 kW cooling, 1.68 kW input, COP 1.00 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AGB4561ZKZ (R22 hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | R22 compressor — 15.5 kW cooling, 6.77 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh AJ2440Z-FZ3C (R448A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R448A compressor — 0.48 kW cooling, 0.50 kW input, COP 0.95 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AJK513Z-GZ3C (R452A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | R452A compressor — 2.9 kW cooling, 1.40 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh FH2511P-XG1A (R452A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R452A compressor — 1.2 kW cooling, 1.29 kW input, COP 0.96 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AE2420Z-AA1B (R452A hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | R452A compressor — 0.34 kW cooling, 0.30 kW input, COP 1.11 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AG2518U-TZ1A (R290 hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | R290 compressor — 1.6 kW cooling, 1.77 kW input, COP 0.92 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
How the model reads against Tecumseh's data
| Tecumseh hermetic compressor maps, the maker's own coefficient sets | 1 883 maps from 313 models on fifteen fluids (R404A 324, R452A 250, R448A 244, R449A 240, R134a 178, R455A 115, R290 109, R454C 106, R22 97, R513A 89, R407C 61, R1234yf 53, R600a 10, R410A 4, R407A 3) at 93 application × refrigerant × frequency listings | power reads the selector's point within 0.95 % on every map (units and coefficient order, BTU/h sets scaled and Fahrenheit sets substituted exactly); the 1 019 zeotrope maps read it to 0.00 % at the selector's dew pair and 3–10 % low at its mid-point pair, which is how the polynomials were shown to be dew-point maps; 1 378 maps rate at their own basis and read the selector's capacity within 1 %; on the 505 the selector corrected from a liquid-temperature or return-gas basis to the regime, this solver's AHRI 540 §6 correction reproduces the selector's corrected capacity within +0.2 % on average (the raw polynomial sits +8.7 % over it), single maps ±11 % where a return-gas basis is carried as one reference superheat. The envelope limits, which the selector states on the mid-point, are converted through the selector's own mid ↔ dew pairs (within 0.05 K of every pair, within 0.7 K of its stated 63 °C-mid condensing ceiling). The bubble line the subcooling is measured from reads the selector's liquid temperatures within 0.4 K on R448A, R449A, R452A, R407C and R404A, 0.6 K on R454C and 1.0 K on R455A — the two property sources' own disagreement on the blends' saturation lines |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.