All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 45Systems 3,474Components 15,410Accessories 0

Showing 5,929–5,952 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZP104KZE-TFE (R410A scroll, 60 Hz, AC) CatalogCopelandR410A compressor — 30.9 kW cooling, 9.70 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SH240-4 (R410A scroll, 60 Hz, A/C) CatalogDanfossR410A compressor — 72.2 kW cooling, 22.10 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT6226GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogEmbracoR404A compressor — 3.2 kW cooling, 1.82 kW input, COP 1.75 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4546P-TZ1A (R455A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR455A compressor — 8.5 kW cooling, 3.58 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZPD137KCE-TF7 (R410A scroll, 60 Hz, AC) CatalogCopelandR410A compressor — 40.4 kW cooling, 12.49 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SM161-3 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 47.6 kW cooling, 14.07 kW input, COP 3.39 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X3121U (R290 hermetic, MBP, EN12900, 50-60 Hz) CatalogEmbracoR290 compressor — 0.24 kW cooling, 0.16 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464Z-GZ3C (R449A hermetic, LBP, EN12900, 50 Hz) CatalogTecumsehR449A compressor — 0.80 kW cooling, 0.84 kW input, COP 0.96 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland ZPDT31MCE-TFD (R410A scroll, 60 Hz, AC) CatalogCopelandR410A compressor — 90.5 kW cooling, 28.11 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SZ115-6 (R134a scroll, 50 Hz, HT) CatalogDanfossR134a compressor — 19.4 kW cooling, 5.82 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT75HLP (R134a hermetic, LBP, EN12900, 50 Hz) CatalogEmbracoR134a compressor — 0.15 kW cooling, 0.12 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4524P-XG1A (R454C hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR454C compressor — 5.9 kW cooling, 2.14 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZPDU42MCE-TE5 (R410A scroll, 50 Hz, AC) CatalogCopelandR410A compressor — 100.5 kW cooling, 31.07 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss VZH052CHM (R454B inverter scroll) CatalogDanfossR454B compressor — 27.0 kW cooling, 9.66 kW input, COP 2.80 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6217GK (R404A hermetic, MBP, EN12900, 50 Hz) CatalogEmbracoR404A compressor — 1.7 kW cooling, 1.00 kW input, COP 1.71 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4450P-FZ1A (R449A hermetic, HBP, ASHRAE, 50 Hz) CatalogTecumsehR449A compressor — 1.4 kW cooling, 0.58 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZPI54KXE-TF7 (R410A scroll, 60 Hz, AC) CatalogCopelandR410A compressor — 16.0 kW cooling, 5.17 kW input, COP 3.09 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss DCJ121T4B (R410A scroll, 60 Hz) CatalogDanfossR410A compressor — 35.7 kW cooling, 11.12 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT6226GKV (R404A hermetic, MBP, EN12900, 50 Hz) CatalogEmbracoR404A compressor — 2.8 kW cooling, 1.39 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4546P-TZ1A (R455A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR455A compressor — 10.6 kW cooling, 4.60 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZPS16K7E-PFV (R410A scroll, 60 Hz, AC) CatalogCopelandR410A compressor — 4.7 kW cooling, 1.56 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss DSF530-7 (R32 scroll, 60 Hz, HT) CatalogDanfossR32 compressor — 156.3 kW cooling, 45.56 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X3121U (R290 hermetic, MBP, EN12900, 60 Hz) CatalogEmbracoR290 compressor — 0.24 kW cooling, 0.15 kW input, COP 1.60 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464Z-GZ3C (R452A hermetic, LBP, EN12900, 50 Hz) CatalogTecumsehR452A compressor — 0.65 kW cooling, 0.74 kW input, COP 0.87 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
‹ Previous1…246247248249250…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors