Compressors
Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.
The builder models these: pick one into a design and it solves on the listing's figures.
Showing 5,953–5,976 of 14,438
| Name | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|
| Copeland ZPSU60K5E-TFD (R410A scroll, 50 Hz, AC) Catalog | Copeland | R410A compressor — 14.7 kW cooling, 4.89 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss DSH140-4 (R454B scroll, 60 Hz, A/C) Catalog | Danfoss | R454B compressor — 40.5 kW cooling, 12.19 kW input, COP 3.32 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NEK6217U (R290 hermetic, MBP, EN12900, 50 Hz) Catalog | Embraco | R290 compressor — 1.7 kW cooling, 0.74 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh FH4524P-XG1A (R455A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R455A compressor — 5.2 kW cooling, 1.93 kW input, COP 2.67 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ZPV0342E-2E9 (R410A variable-speed scroll) Catalog | Copeland | R410A compressor — 13.9 kW cooling, 4.44 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Danfoss HLJ083T4A (R454B scroll, 60 Hz) Catalog | Danfoss | R454B compressor — 23.3 kW cooling, 7.22 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NT6226GKV (R404A hermetic, MBP, EN12900, 60 Hz) Catalog | Embraco | R404A compressor — 3.2 kW cooling, 1.81 kW input, COP 1.77 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AE4450P-FZ1A (R452A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Tecumseh | R452A compressor — 1.3 kW cooling, 0.61 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ZR108KRE-TFD (R407C scroll, 50 Hz, AC) Catalog | Copeland | R407C compressor — 25.8 kW cooling, 7.58 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss HRH034U7 (R410A scroll, 60 Hz, A/C) Catalog | Danfoss | R410A compressor — 10.2 kW cooling, 3.40 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2X3125U (R290 hermetic, LBP, EN12900, 50 Hz) Catalog | Embraco | R290 compressor — 0.25 kW cooling, 0.14 kW input, COP 1.79 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AG4547N-TZ1A (R1234yf hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R1234yf compressor — 9.1 kW cooling, 4.12 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ZRD42KCE-TFD (R407C scroll, 50 Hz, AC) Catalog | Copeland | R407C compressor — 10.0 kW cooling, 3.13 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss HRM047T4 (R22 scroll, 50 Hz, A/C) Catalog | Danfoss | R22 compressor — 11.5 kW cooling, 3.46 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NT6230U (R290 hermetic, MBP, EN12900, 50 Hz) Catalog | Embraco | R290 compressor — 3.2 kW cooling, 1.43 kW input, COP 2.24 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AJ2464Z-HZ3C (R404A hermetic, LBP, EN12900, 60 Hz) Catalog | Tecumseh | R404A compressor — 0.82 kW cooling, 0.96 kW input, COP 0.85 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland ZRH116KTE-TFD (R134A scroll, 50 Hz, AC) Catalog | Copeland | R134a compressor — 19.0 kW cooling, 6.24 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss HRP054T5 (R407C scroll, 50 Hz, A/C) Catalog | Danfoss | R407C compressor — 12.8 kW cooling, 4.03 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2X3125U (R290 hermetic, LBP, EN12900, 50-60 Hz) Catalog | Embraco | R290 compressor — 0.28 kW cooling, 0.18 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh FH4524P-XG1A (R455A hermetic, HBP, EN12900, 60 Hz) Catalog | Tecumseh | R455A compressor — 6.2 kW cooling, 2.33 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ZS09KAE-TF5 (R404A scroll, 50 Hz, MT) Catalog | Copeland | R404A compressor — 3.3 kW cooling, 1.38 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss LLZ015T2C (R404A scroll, 50 Hz, LT) Catalog | Danfoss | R404A compressor — 3.8 kW cooling, 2.51 kW input, COP 1.53 at -35/30 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Embraco EM2X3125U (R290 hermetic, LBP, EN12900, 60 Hz) Catalog | Embraco | R290 compressor — 0.26 kW cooling, 0.17 kW input, COP 1.55 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AE4450P-FZ1A (R454C hermetic, HBP, ASHRAE, 50 Hz) Catalog | Tecumseh | R454C compressor — 1.2 kW cooling, 0.51 kW input, COP 2.45 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors