Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 2,449–2,472 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Embraco NJ2192K (R502 hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R502 compressor — 0.59 kW cooling, 0.61 kW input, COP 0.98 at -35/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM132A8G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 575 V 3P) Catalog | Compressors | Invotech | R22 compressor — 25.4 kW cooling, 8.42 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh TC4419Y-DT1B (R134a hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 0.47 kW cooling, 0.26 kW input, COP 1.78 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ZX150KCE-TWD (R407C scroll, 60 Hz, MT) Catalog | Compressors | Copeland | R407C compressor — 79.4 kW cooling, 27.44 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Danfoss VLZ035TGA (R449A inverter scroll, A/C) Catalog | Compressors | Danfoss | R449A compressor — 11.5 kW cooling, 4.75 kW input, COP 2.43 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NJX6244U (R290 hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R290 compressor — 2.8 kW cooling, 1.45 kW input, COP 1.96 at -15/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YSF90E1G-V100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P) Catalog | Compressors | Invotech | R404A compressor — 32.9 kW cooling, 12.87 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh TCW390U-CE3A (R290 hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R290 compressor — 0.21 kW cooling, 0.14 kW input, COP 1.53 at -25/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland ZXV062QE-5X9 (R404A variable-speed scroll, 3 steps) Catalog | Compressors | Copeland | R404A compressor — 20.2 kW cooling, 8.10 kW input, COP 2.49 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Danfoss VTZ086-G (R407C variable-speed hermetic reciprocating, MT) Catalog | Compressors | Danfoss | R407C compressor — 17.6 kW cooling, 7.88 kW input, COP 2.24 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NT2152ZV (R134a hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.69 kW cooling, 0.53 kW input, COP 1.30 at -25/45 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YW152C2-100 (R410A heat-pump water heater scroll, 50 Hz, 220 V 1P) Catalog | Compressors | Invotech | R410A compressor — 16.0 kW cooling, 5.53 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh THB4419YFZ (R134a hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 0.45 kW cooling, 0.23 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ZXW062QE-5X9 (R404A variable-speed scroll) Catalog | Compressors | Copeland | R404A compressor — 28.3 kW cooling, 10.07 kW input, COP 2.82 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Danfoss VZF170CJ (R32 inverter scroll) Catalog | Compressors | Danfoss | R32 compressor — 84.6 kW cooling, 27.71 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NTU6224ZV (R134a hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 3.4 kW cooling, 1.30 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF17E1G-Q100 (R404A low-temperature freezing scroll, 60 Hz, 460 V 3P) Catalog | Compressors | Invotech | R404A compressor — 2.2 kW cooling, 2.06 kW input, COP 1.09 at -30/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Tecumseh THG1365YGS (R134a hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 0.10 kW cooling, 0.10 kW input, COP 0.97 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 2DA3F23KE-TFC (R407F Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R407F compressor — 5.2 kW cooling, 3.12 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss VZH028CHM (R452B inverter scroll, A/C) Catalog | Compressors | Danfoss | R452B compressor — 12.9 kW cooling, 4.97 kW input, COP 2.59 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NTX2213UV (R290 hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R290 compressor — 1.1 kW cooling, 0.85 kW input, COP 1.24 at -35/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH128C1-100 (R410A air-conditioning scroll, 50 Hz, 380 V 3P) Catalog | Compressors | Invotech | R410A compressor — 12.9 kW cooling, 4.22 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh AE2410Z-AA1A (R448A hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | Tecumseh | R448A compressor — 0.25 kW cooling, 0.20 kW input, COP 1.23 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 2DB3F25KE-TFC (R407F Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R407F compressor — 5.7 kW cooling, 3.33 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here