Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 2,497–2,520 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Copeland 2YA3F17KE-TFC (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 4.9 kW cooling, 2.84 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HCP120T4 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 33.6 kW cooling, 10.61 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VESA6H (R134a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.15 kW cooling, 0.10 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM132E1G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR404A compressor — 24.6 kW cooling, 9.46 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AL4510Z-FZ3A (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 2.1 kW cooling, 1.05 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2YB3F18KE-TFC (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 5.1 kW cooling, 2.98 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLH061T4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 14.9 kW cooling, 4.78 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VESC9C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.16 kW cooling, 0.10 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF90E5G-V100 (R404A low-temperature freezing scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 39.5 kW cooling, 15.46 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AWA9514ZXN (R404A hermetic, HBP, ARI, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 6.6 kW cooling, 3.03 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2YC3R51KE-TFC (R454C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454C compressor — 8.2 kW cooling, 2.93 kW input, COP 2.79 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLJ072T4A (R410A scroll, 50 Hz) CatalogCompressorsDanfossR410A compressor — 15.9 kW cooling, 5.56 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VESD13C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.21 kW cooling, 0.14 kW input, COP 1.49 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW155J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR134a compressor — 14.4 kW cooling, 4.40 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AWS4522ELZ (R22 hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 5.3 kW cooling, 1.82 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2YD3R59KE-TFC (R454C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454C compressor — 9.5 kW cooling, 3.40 kW input, COP 2.78 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLM072T4 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 21.3 kW cooling, 6.27 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VESF5C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.51 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF17E1G-Q100 (R449A low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR449A compressor — 1.7 kW cooling, 1.75 kW input, COP 0.99 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh FH2480P-XG1A (R455A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR455A compressor — 1.2 kW cooling, 1.21 kW input, COP 1.03 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 2YF3F13KL-TFC (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 3.9 kW cooling, 2.26 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLP072T5 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 16.7 kW cooling, 5.53 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VESG7C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.12 kW cooling, 0.07 kW input, COP 1.70 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH128C2-100 (R410A air-conditioning scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR410A compressor — 12.9 kW cooling, 4.29 kW input, COP 3.01 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
‹ Previous1…103104105106107…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet