Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 2,545–2,568 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Invotech YH128C3-100 (R410A air-conditioning scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR410A compressor — 15.5 kW cooling, 5.14 kW input, COP 3.01 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2513Z-KZ1A (R448A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 1.7 kW cooling, 1.72 kW input, COP 0.97 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DBDF33KE-TFD (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 8.3 kW cooling, 4.60 kW input, COP 1.81 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T1A (R449A scroll, 60 Hz, MT) CatalogCompressorsDanfossR449A compressor — 6.6 kW cooling, 2.56 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EGX70HLC (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.16 kW cooling, 0.10 kW input, COP 1.61 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM132E6G-100 (R404A medium-temperature refrigeration scroll, 50 Hz, 220 V 3P) CatalogCompressorsInvotechR404A compressor — 20.5 kW cooling, 7.88 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AGB4546ZTZ (R22 hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 10.4 kW cooling, 4.14 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DBDR12ME-TFC (R407C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407C compressor — 19.9 kW cooling, 7.28 kW input, COP 2.73 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT019-5 (R22 hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 3.9 kW cooling, 1.45 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EGYS70HLP (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.16 kW cooling, 0.10 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW155J7-100 (R134a heat-pump water heater scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR134a compressor — 17.3 kW cooling, 5.29 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2432P-FZ3A (R449A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 0.40 kW cooling, 0.41 kW input, COP 0.97 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DEHR10ME-TFD (R407C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407C compressor — 16.5 kW cooling, 6.14 kW input, COP 2.69 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ018-1 (R454C hermetic reciprocating, 60 Hz) CatalogCompressorsDanfossR454C compressor — 4.2 kW cooling, 1.73 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EGZS70HLC (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.16 kW cooling, 0.10 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF17E1G-V100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 2.3 kW cooling, 1.93 kW input, COP 1.20 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh AJK480Z-TZ1C (R448A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 2.3 kW cooling, 1.12 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DF3F40KE-TFD (R407C Discus recip, 50 Hz, LT) CatalogCompressorsCopelandR407C compressor — 6.9 kW cooling, 5.31 kW input, COP 1.30 at -35/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss NTZ048-4B (R404A hermetic reciprocating, 50 Hz, LT) CatalogCompressorsDanfossR404A compressor — 0.51 kW cooling, 0.59 kW input, COP 0.88 at -40/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EHU2155U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.34 kW cooling, 0.27 kW input, COP 1.26 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH128C5-100 (R410A air-conditioning scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR410A compressor — 15.5 kW cooling, 5.06 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AKA9462ZXA (R404A hermetic, HBP, ARI, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 3.0 kW cooling, 1.70 kW input, COP 1.78 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DFDF40KE-TFD (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 9.8 kW cooling, 5.54 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH019-4E (R454B scroll, 50 Hz) CatalogCompressorsDanfossR454B compressor — 20.2 kW cooling, 7.21 kW input, COP 2.80 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…105106107108109…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one