Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 2,593–2,616 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss VLZ035TJA (R404A inverter scroll, A/C) CatalogCompressorsDanfossR404A compressor — 11.2 kW cooling, 5.10 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMIE30HJP (R134a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.06 kW cooling, 0.06 kW input, COP 1.11 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW160A1-100 (R22 heat-pump water heater scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 17.6 kW cooling, 5.46 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh TCW390U-GS8E (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR290 compressor — 0.21 kW cooling, 0.14 kW input, COP 1.48 at -25/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DS3F46KE-TFD (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 10.7 kW cooling, 6.11 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss VTZ121-G (R134a variable-speed hermetic reciprocating, MT) CatalogCompressorsDanfossR134a compressor — 16.7 kW cooling, 6.98 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMIS30HHR (R134a hermetic, HBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.34 kW cooling, 0.16 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF17E2G-Q100 (R448A low-temperature freezing scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR448A compressor — 1.7 kW cooling, 1.74 kW input, COP 1.00 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh THB4419YWZ (R134a hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 0.45 kW cooling, 0.22 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DSDF46KE-TFD (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 10.7 kW cooling, 6.11 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss VZH028CHM (R454B inverter scroll, A/C) CatalogCompressorsDanfossR454B compressor — 12.7 kW cooling, 4.94 kW input, COP 2.57 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMR130HLC (R134a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.26 kW cooling, 0.21 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH128C7-100 (R410A air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR410A compressor — 15.5 kW cooling, 5.06 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh THG1365YNS (R134a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 0.09 kW cooling, 0.10 kW input, COP 0.89 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DSDR17ME-TFD (R407A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407A compressor — 27.6 kW cooling, 10.14 kW input, COP 2.72 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DCJ091T4A (R454B scroll, 50 Hz) CatalogCompressorsDanfossR454B compressor — 19.4 kW cooling, 6.51 kW input, COP 2.97 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT1130U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.20 kW cooling, 0.18 kW input, COP 1.10 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM158A1G-100 (R22 medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 25.9 kW cooling, 8.60 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AE2410Z-AA1A (R452A hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR452A compressor — 0.18 kW cooling, 0.17 kW input, COP 1.03 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DSDS12ME-TFD (R407A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407A compressor — 23.7 kW cooling, 8.90 kW input, COP 2.66 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSF115-3 (R32 scroll, 60 Hz, HT) CatalogCompressorsDanfossR32 compressor — 34.9 kW cooling, 10.79 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMU30HER (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.66 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW160A1-100 (R22 heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR22 compressor — 21.1 kW cooling, 6.54 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2513Z-KZ1A (R448A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 2.2 kW cooling, 2.18 kW input, COP 1.02 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
‹ Previous1…107108109110111…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one