Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 2,521–2,544 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh TC4419Y-DT1B (R513A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR513A compressor — 0.47 kW cooling, 0.27 kW input, COP 1.71 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2YL3F15KE-TFC (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 4.3 kW cooling, 2.52 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH029U4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 7.1 kW cooling, 2.43 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VESH9C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.15 kW cooling, 0.09 kW input, COP 1.71 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM132E5G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 24.6 kW cooling, 9.46 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh TCW390U-DS6B (R290 hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR290 compressor — 0.25 kW cooling, 0.15 kW input, COP 1.68 at -25/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DA3F28KE-TFC (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 6.6 kW cooling, 3.79 kW input, COP 1.73 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM034T4 (R22 scroll, 50 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 8.2 kW cooling, 2.50 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VNEK606GK (R404A variable-capacity hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR404A compressor — 1.2 kW cooling, 0.73 kW input, COP 1.65 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF90E7G-V100 (R404A low-temperature freezing scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR404A compressor — 39.5 kW cooling, 15.46 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh THB4419YHZ (R134a hermetic, HBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 0.54 kW cooling, 0.28 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DADF28KE-TFC (R407C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407C compressor — 5.8 kW cooling, 3.62 kW input, COP 1.59 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRP034T2 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 9.6 kW cooling, 3.19 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VNEX421U (R290 variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 1.2 kW cooling, 0.83 kW input, COP 1.42 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW155J1-100 (R134a heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR134a compressor — 17.3 kW cooling, 5.29 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh THG1365YLS (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 0.10 kW cooling, 0.11 kW input, COP 0.91 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DADR10ME-TFC (R407C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407C compressor — 16.5 kW cooling, 6.14 kW input, COP 2.69 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ013T2A (R452A scroll, 60 Hz, LT) CatalogCompressorsDanfossR452A compressor — 3.3 kW cooling, 2.42 kW input, COP 1.35 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EGAS100HLR (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.23 kW cooling, 0.15 kW input, COP 1.55 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF17E1G-Q100 (R452A low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR452A compressor — 1.8 kW cooling, 1.72 kW input, COP 1.04 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh AE2410Z-AA1A (R449A hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 0.24 kW cooling, 0.19 kW input, COP 1.26 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DB3F33KE-ES8 (R507 Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR507 compressor — 9.6 kW cooling, 5.40 kW input, COP 1.78 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLM026T4 (R22 scroll, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 9.7 kW cooling, 2.96 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EGUS80HLP (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.19 kW cooling, 0.12 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
‹ Previous1…104105106107108…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one