Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 3,145–3,168 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Invotech YH140A1-100 (R22 air-conditioning scroll, 60 Hz, 460 V 3P) Catalog | Compressors | Invotech | R22 compressor — 16.9 kW cooling, 4.94 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AWS4524ZXG (R404A hermetic, HBP, ASHRAE, 60 Hz) Catalog | Compressors | Tecumseh | R404A compressor — 7.6 kW cooling, 2.70 kW input, COP 2.82 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DVNR36ME-AWX (R507 Discus recip, 50 Hz, LD) Catalog | Compressors | Copeland | R507 compressor — 40.9 kW cooling, 22.32 kW input, COP 1.83 at -35/30 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss HCJ106T4 (R410A scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R410A compressor — 26.1 kW cooling, 8.07 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FFU130HAX (R134a hermetic, MBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.22 kW cooling, 0.17 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM200A7G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 220 V 3P) Catalog | Compressors | Invotech | R22 compressor — 38.4 kW cooling, 12.59 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh FH2480Z-KZ1A (R449A hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R449A compressor — 1.3 kW cooling, 1.19 kW input, COP 1.14 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 6DVXF13ME-TSE (R404A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R404A compressor — 40.9 kW cooling, 22.32 kW input, COP 1.83 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HCM120T9 (R22 scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 33.9 kW cooling, 10.25 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FFUS130HAX (R134a hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.25 kW cooling, 0.23 kW input, COP 1.07 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YW190T1-100 (R407C heat-pump water heater scroll, 50 Hz, 380 V 3P) Catalog | Compressors | Invotech | R407C compressor — 20.1 kW cooling, 6.66 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh TC4430U-FZ1B (R290 hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R290 compressor — 0.81 kW cooling, 0.31 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DVXR36ME-AWX (R507 Discus recip, 50 Hz, LD) Catalog | Compressors | Copeland | R507 compressor — 40.9 kW cooling, 22.32 kW input, COP 1.83 at -35/30 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss HLH061T4A (R454B scroll, 60 Hz) Catalog | Compressors | Danfoss | R454B compressor — 17.0 kW cooling, 5.43 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FFV8,5HAK (R134a hermetic, LBP, ASHRAE, 50-60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.19 kW cooling, 0.13 kW input, COP 1.50 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF20A7G-V100 (R22 low-temperature freezing scroll, 60 Hz, 220 V 3P) Catalog | Compressors | Invotech | R22 compressor — 3.2 kW cooling, 2.45 kW input, COP 1.31 at -30/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Tecumseh TCW415U-CE3A (R290 hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R290 compressor — 0.39 kW cooling, 0.26 kW input, COP 1.52 at -25/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 6DWNR32ME-TSK (R407C Discus recip, 60 Hz, AC) Catalog | Compressors | Copeland | R407C compressor — 68.6 kW cooling, 30.99 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss HLJ072T4B (R410A scroll, 60 Hz) Catalog | Compressors | Danfoss | R410A compressor — 21.2 kW cooling, 6.65 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco FGS80LAS (R1234yf hermetic, LBP, EN12900, 50-60 Hz) Catalog | Compressors | Embraco | R1234yf compressor — 0.22 kW cooling, 0.16 kW input, COP 1.38 at -25/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH140A2-100 (R22 air-conditioning scroll, 50 Hz, 220 V 1P) Catalog | Compressors | Invotech | R22 compressor — 14.1 kW cooling, 4.27 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Tecumseh AE2415P-FZ1B (R449A hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R449A compressor — 0.29 kW cooling, 0.22 kW input, COP 1.32 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 6DYNR32ME-TSK (R407C Discus recip, 60 Hz, AC) Catalog | Compressors | Copeland | R407C compressor — 99.6 kW cooling, 30.99 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss HLM075T2 (R22 scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 22.1 kW cooling, 6.45 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point. | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory