Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 3,169–3,192 of 10,248
Copeland YS16KAE-PFJ (R22 scroll, 50 Hz, HT)
R22 compressor — 6.6 kW cooling, 2.23 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.
Copeland YS16KAE-PFJ (R22 scroll, 60 Hz, HT)
R22 compressor — 7.9 kW cooling, 2.67 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.
Copeland YS16KAE-PFJ (R404A scroll, 50 Hz, EM)
R404A compressor — 2.6 kW cooling, 1.42 kW input, COP 1.83 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS16KAE-PFJ (R407A scroll, 50 Hz, EM)
R407A compressor — 2.0 kW cooling, 1.45 kW input, COP 1.40 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS16KAE-TF5 (R407C scroll, 50 Hz, HT)
R407C compressor — 6.3 kW cooling, 2.21 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
Copeland YS16KAE-TF5 (R407C scroll, 60 Hz, HT)
R407C compressor — 7.5 kW cooling, 2.65 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
Copeland YS16KAE-PFJ (R448A scroll, 50 Hz, EM)
R448A compressor — 2.2 kW cooling, 1.49 kW input, COP 1.46 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS16KAE-PFJ (R449A scroll, 50 Hz, EM)
R449A compressor — 2.2 kW cooling, 1.49 kW input, COP 1.46 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS16KAE-TF5 (R455A scroll, 50 Hz, EM)
R455A compressor — 2.1 kW cooling, 1.35 kW input, COP 1.55 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS16KAE-PFJ (R507 scroll, 50 Hz, EM)
R507 compressor — 2.7 kW cooling, 1.44 kW input, COP 1.87 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS17KSE-PFV (R134A scroll, 50 Hz, EM)
R134a compressor — 1.4 kW cooling, 1.01 kW input, COP 1.34 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS17KSE-PFV (R404A scroll, 50 Hz, EM)
R404A compressor — 2.8 kW cooling, 1.61 kW input, COP 1.73 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS17KSE-TF5 (R454A scroll, 50 Hz, EM)
R454A compressor — 2.5 kW cooling, 1.67 kW input, COP 1.47 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS17KSE-TF5 (R454A scroll, 60 Hz, EM)
R454A compressor — 2.9 kW cooling, 2.00 kW input, COP 1.47 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS17KSE-TF5 (R454C scroll, 50 Hz, EM)
R454C compressor — 2.1 kW cooling, 1.36 kW input, COP 1.53 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS17KSE-TF5 (R454C scroll, 60 Hz, EM)
R454C compressor — 2.5 kW cooling, 1.64 kW input, COP 1.53 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS17KSE-TF5 (R455A scroll, 50 Hz, EM)
R455A compressor — 2.3 kW cooling, 1.46 kW input, COP 1.56 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS17KSE-TF5 (R455A scroll, 60 Hz, EM)
R455A compressor — 2.7 kW cooling, 1.75 kW input, COP 1.56 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS17KSE-PFV (R507 scroll, 50 Hz, EM)
R507 compressor — 2.9 kW cooling, 1.65 kW input, COP 1.77 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS18KSE-PFV (R404A scroll, 50 Hz, EM)
R404A compressor — 3.1 kW cooling, 1.75 kW input, COP 1.77 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS18KSE-TF5 (R454A scroll, 50 Hz, EM)
R454A compressor — 2.8 kW cooling, 1.78 kW input, COP 1.56 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS18KSE-TF5 (R454A scroll, 60 Hz, EM)
R454A compressor — 3.3 kW cooling, 2.14 kW input, COP 1.56 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS18KSE-TF5 (R454C scroll, 50 Hz, EM)
R454C compressor — 2.3 kW cooling, 1.45 kW input, COP 1.61 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS18KSE-TF5 (R454C scroll, 60 Hz, EM)
R454C compressor — 2.8 kW cooling, 1.75 kW input, COP 1.61 at -25/40 °C (evaporating/condensing), inside its published envelope.