Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 3,193–3,216 of 10,248
Copeland YS18KSE-TF5 (R455A scroll, 50 Hz, EM)
R455A compressor — 2.6 kW cooling, 1.55 kW input, COP 1.64 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS18KSE-TF5 (R455A scroll, 60 Hz, EM)
R455A compressor — 3.1 kW cooling, 1.87 kW input, COP 1.64 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS18KSE-PFV (R507 scroll, 50 Hz, EM)
R507 compressor — 3.2 kW cooling, 1.79 kW input, COP 1.81 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-TF5 (R134A scroll, 50 Hz, HT)
R134a compressor — 5.2 kW cooling, 1.76 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point.
Copeland YS19KAE-TF5 (R134A scroll, 60 Hz, HT)
R134a compressor — 6.2 kW cooling, 2.11 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point.
Copeland YS19KAE-PFV (R22 scroll, 60 Hz, HT)
R22 compressor — 9.5 kW cooling, 3.26 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.
Copeland YS19KAE-PFJ (R404A scroll, 50 Hz, EM)
R404A compressor — 3.1 kW cooling, 1.69 kW input, COP 1.83 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-PFJ (R404A scroll, 60 Hz, EM)
R404A compressor — 3.7 kW cooling, 2.03 kW input, COP 1.83 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-PFJ (R407A scroll, 50 Hz, EM)
R407A compressor — 2.5 kW cooling, 1.73 kW input, COP 1.47 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-PFJ (R407A scroll, 60 Hz, EM)
R407A compressor — 3.1 kW cooling, 2.08 kW input, COP 1.47 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-TF5 (R407C scroll, 50 Hz, HT)
R407C compressor — 7.5 kW cooling, 2.67 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
Copeland YS19KAE-TF5 (R407C scroll, 60 Hz, HT)
R407C compressor — 9.0 kW cooling, 3.20 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
Copeland YS19KAE-PFJ (R448A scroll, 50 Hz, EM)
R448A compressor — 2.6 kW cooling, 1.78 kW input, COP 1.47 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-PFJ (R448A scroll, 60 Hz, EM)
R448A compressor — 3.2 kW cooling, 2.13 kW input, COP 1.48 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-PFJ (R449A scroll, 50 Hz, EM)
R449A compressor — 2.6 kW cooling, 1.78 kW input, COP 1.47 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-PFJ (R449A scroll, 60 Hz, EM)
R449A compressor — 3.2 kW cooling, 2.13 kW input, COP 1.48 at -25/40 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-PFJ (R507 scroll, 50 Hz, EM)
R507 compressor — 3.3 kW cooling, 1.78 kW input, COP 1.83 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS19KAE-PFJ (R507 scroll, 60 Hz, EM)
R507 compressor — 3.9 kW cooling, 2.14 kW input, COP 1.83 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS21KAE-TF5 (R134A scroll, 50 Hz, HT)
R134a compressor — 6.1 kW cooling, 2.02 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
Copeland YS21KAE-TF5 (R134A scroll, 60 Hz, HT)
R134a compressor — 7.3 kW cooling, 2.43 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
Copeland YS21KAE-PFJ (R22 scroll, 50 Hz, HT)
R22 compressor — 9.3 kW cooling, 3.12 kW input, COP 2.97 at the AHRI 7.2/54.4 °C rating point.
Copeland YS21KAE-PFV (R22 scroll, 60 Hz, HT)
R22 compressor — 11.1 kW cooling, 3.74 kW input, COP 2.97 at the AHRI 7.2/54.4 °C rating point.
Copeland YS21KAE-PFJ (R404A scroll, 50 Hz, EM)
R404A compressor — 3.7 kW cooling, 2.01 kW input, COP 1.83 at -25/35 °C (evaporating/condensing), inside its published envelope.
Copeland YS21KAE-PFJ (R404A scroll, 60 Hz, EM)
R404A compressor — 4.4 kW cooling, 2.41 kW input, COP 1.83 at -25/35 °C (evaporating/condensing), inside its published envelope.
Publishing here