Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 5,545–5,568 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Invotech YM60E2G-100 (R452A medium-temperature refrigeration scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR452A compressor — 9.3 kW cooling, 3.86 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AE4430N-FZ1A (R513A hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR513A compressor — 1.1 kW cooling, 0.48 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DRXR40ME-TSE (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 68.6 kW cooling, 24.62 kW input, COP 2.79 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T2C (R404A scroll, 60 Hz, MT) CatalogCompressorsDanfossR404A compressor — 6.1 kW cooling, 2.54 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK2168GK (R404A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 0.40 kW cooling, 0.43 kW input, COP 0.92 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF41A7G-V100 (R22 low-temperature freezing scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 6.7 kW cooling, 4.52 kW input, COP 1.49 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AG2525P-TZ1A (R449A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 3.1 kW cooling, 2.67 kW input, COP 1.14 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DSNR40ME-TSN (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 135.1 kW cooling, 45.77 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MT036-6 (R22 hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 9.3 kW cooling, 3.37 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEU6181GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 1.1 kW cooling, 0.57 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH307T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR407C compressor — 35.5 kW cooling, 10.74 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AGB4573ZKZ (R407C hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR407C compressor — 14.8 kW cooling, 6.33 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DUNF13ME-TSE (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 30.3 kW cooling, 17.38 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ018-4 (R449A hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR449A compressor — 3.6 kW cooling, 1.47 kW input, COP 2.43 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT2210GK (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 0.67 kW cooling, 0.65 kW input, COP 1.03 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM60E3G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR404A compressor — 11.1 kW cooling, 4.58 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2446Z-TZ1B (R449A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 0.59 kW cooling, 0.61 kW input, COP 0.97 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DUNR49ME-TSE (R22 Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR22 compressor — 67.3 kW cooling, 24.59 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss NTZ068-4B (R452A hermetic reciprocating, 60 Hz, LT) CatalogCompressorsDanfossR452A compressor — 1.7 kW cooling, 1.56 kW input, COP 1.08 at -35/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EM2U30HLP (R134a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.15 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF41E1G-Q100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR404A compressor — 4.6 kW cooling, 3.66 kW input, COP 1.25 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh FH4518Y-XG1A (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 3.9 kW cooling, 1.47 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DUXF13ME-TSE (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 30.3 kW cooling, 17.38 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH023-9E (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 30.8 kW cooling, 10.63 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…230231232233234…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one