Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 5,593–5,616 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Danfoss DCJ106T7A (R410A scroll, 60 Hz) Catalog | Compressors | Danfoss | R410A compressor — 31.5 kW cooling, 9.67 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NEK2172GK (R404A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R404A compressor — 0.46 kW cooling, 0.44 kW input, COP 1.05 at -35/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF41E1G-Q100 (R448A low-temperature freezing scroll, 50 Hz, 380 V 3P) Catalog | Compressors | Invotech | R448A compressor — 4.2 kW cooling, 3.62 kW input, COP 1.15 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AE4430P-FZ1A (R448A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R448A compressor — 0.79 kW cooling, 0.32 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DWNR32ME-TSK (R407F Discus recip, 60 Hz, AC) Catalog | Compressors | Copeland | R407F compressor — 103.5 kW cooling, 33.41 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss DSF270-4 (R32 scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R32 compressor — 78.2 kW cooling, 23.66 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NEU6181U (R290 hermetic, MBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R290 compressor — 0.89 kW cooling, 0.37 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH325C1-100 (R410A air-conditioning scroll, 60 Hz, 460 V 3P) Catalog | Compressors | Invotech | R410A compressor — 39.4 kW cooling, 12.23 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AG2525P-TZ1A (R452A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R452A compressor — 2.4 kW cooling, 2.26 kW input, COP 1.04 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 6DYNR32ME-TSK (R407F Discus recip, 60 Hz, AC) Catalog | Compressors | Copeland | R407F compressor — 103.5 kW cooling, 33.41 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss DSH120-4 (R454B scroll, 50 Hz, HT) Catalog | Compressors | Danfoss | R454B compressor — 26.6 kW cooling, 9.00 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco NT2210U (R290 hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R290 compressor — 0.70 kW cooling, 0.60 kW input, COP 1.17 at -35/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YM60E3G-100 (R452A medium-temperature refrigeration scroll, 60 Hz, 220 V 1P) Catalog | Compressors | Invotech | R452A compressor — 11.2 kW cooling, 4.82 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh AGB4573ZKZ (R448A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R448A compressor — 15.4 kW cooling, 6.71 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DZNF13ME-TSE (R407A Discus recip, 50 Hz, LD) Catalog | Compressors | Copeland | R407A compressor — 25.3 kW cooling, 14.49 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss HLH068T4A (R454B scroll, 50 Hz) Catalog | Compressors | Danfoss | R454B compressor — 14.2 kW cooling, 4.88 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2U3111U (R290 hermetic, LBP, EN12900, 50-60 Hz) Catalog | Compressors | Embraco | R290 compressor — 0.13 kW cooling, 0.08 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YF41E1G-Q100 (R449A low-temperature freezing scroll, 50 Hz, 380 V 3P) Catalog | Compressors | Invotech | R449A compressor — 4.2 kW cooling, 3.62 kW input, COP 1.15 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Tecumseh AJ2446Z-TZ1B (R452A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R452A compressor — 0.47 kW cooling, 0.53 kW input, COP 0.90 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 6DZNR49ME-TSE (R404A Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R404A compressor — 90.3 kW cooling, 36.23 kW input, COP 2.49 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HLJ075T4B (R454B scroll, 60 Hz) Catalog | Compressors | Danfoss | R454B compressor — 21.1 kW cooling, 6.51 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EMC3145U (R290 hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R290 compressor — 0.49 kW cooling, 0.31 kW input, COP 1.59 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Invotech YH325C5-100 (R410A air-conditioning scroll, 60 Hz, 380 V 3P) Catalog | Compressors | Invotech | R410A compressor — 39.4 kW cooling, 12.23 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Tecumseh FH4518Y-XG1A (R513A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R513A compressor — 3.9 kW cooling, 1.54 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory