Embraco EM2U3121Z (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.21 kW cooling, 0.15 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2U3125Z (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.26 kW cooling, 0.20 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2U3125Z (R134a hermetic, MBP, EN12900, 60 Hz)
R134a compressor — 0.26 kW cooling, 0.20 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2U50CLP (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2U50HLP (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.11 kW cooling, 0.08 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2U60CLP (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.12 kW cooling, 0.10 kW input, COP 1.24 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2U60HLP (R134a hermetic, LBP, ASHRAE, 50 Hz)
R134a compressor — 0.12 kW cooling, 0.08 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2U60HLP (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.13 kW cooling, 0.10 kW input, COP 1.33 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2U70HLP (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.16 kW cooling, 0.11 kW input, COP 1.47 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2U80HLP (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.16 kW cooling, 0.12 kW input, COP 1.35 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X1121U (R290 hermetic, LBP, EN12900, 50-60 Hz)
R290 compressor — 0.21 kW cooling, 0.13 kW input, COP 1.69 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X1121U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.11 kW cooling, 0.09 kW input, COP 1.24 at -40/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X1121U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.18 kW cooling, 0.13 kW input, COP 1.41 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X1121U (R290 hermetic, MBP, EN12900, 50-60 Hz)
R290 compressor — 0.21 kW cooling, 0.13 kW input, COP 1.69 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X1125U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.13 kW cooling, 0.10 kW input, COP 1.25 at -40/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X1125U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.20 kW cooling, 0.15 kW input, COP 1.39 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X2121U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.16 kW cooling, 0.11 kW input, COP 1.46 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X3113U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.13 kW cooling, 0.08 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X3113U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.16 kW cooling, 0.10 kW input, COP 1.63 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X3113U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 0.13 kW cooling, 0.08 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X3113U (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 0.16 kW cooling, 0.10 kW input, COP 1.63 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X3117U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.17 kW cooling, 0.10 kW input, COP 1.72 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X3117U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.21 kW cooling, 0.12 kW input, COP 1.71 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco EM2X3117U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 0.17 kW cooling, 0.10 kW input, COP 1.72 at -30/40 °C (evaporating/condensing), inside its published envelope.