Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 6,577–6,600 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss DSH140-4 (R410A scroll, 50 Hz, HT) CatalogCompressorsDanfossR410A compressor — 30.4 kW cooling, 10.70 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY70HSC (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.16 kW cooling, 0.10 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4440Y-GS1A (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 0.95 kW cooling, 0.45 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DUNF13ME-TSE (R407C Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR407C compressor — 23.4 kW cooling, 14.04 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HLH068T9 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 19.6 kW cooling, 6.37 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6187Z (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 1.0 kW cooling, 0.48 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4543N-TZ1A (R1234yf hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR1234yf compressor — 8.2 kW cooling, 3.62 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DUNR49ME-TSE (R22 Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLJ083T4 (R410A scroll, 50 Hz) CatalogCompressorsDanfossR410A compressor — 18.2 kW cooling, 6.27 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEU6217U (R290 hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 2.0 kW cooling, 1.01 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB4581ZTZ (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 16.3 kW cooling, 7.68 kW input, COP 2.12 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DUXF13ME-TSE (R407C Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR407C compressor — 23.4 kW cooling, 14.04 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HRH034U2A (R454B scroll, 50 Hz) CatalogCompressorsDanfossR454B compressor — 7.2 kW cooling, 2.69 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT6220UV (R290 hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 2.2 kW cooling, 0.93 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464P-TZ1A (R452A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 0.66 kW cooling, 0.71 kW input, COP 0.93 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DUXR49ME-TSE (R22 Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM045U2 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 13.2 kW cooling, 4.01 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X1121U (R290 hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.21 kW cooling, 0.13 kW input, COP 1.69 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4522Z-XG1A (R452A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR452A compressor — 5.6 kW cooling, 2.31 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DVNF13ME-TSE (R407C Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR407C compressor — 23.4 kW cooling, 14.04 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HRP054T1 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 15.1 kW cooling, 4.76 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT6144GK (R404A hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 0.56 kW cooling, 0.28 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4440Y-GS1A (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 1.1 kW cooling, 0.53 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DVNR49ME-TSE (R22 Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…273274275276277…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one