Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 6,625–6,648 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss SH184-7 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 54.0 kW cooling, 16.45 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT6144GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 0.68 kW cooling, 0.35 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB5553EKZ (R22 hermetic, AC, Tecumseh Europe, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 13.0 kW cooling, 4.40 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YGNR35ME-TSN (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 119.8 kW cooling, 38.02 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SM160-4 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 47.7 kW cooling, 14.22 kW input, COP 3.36 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMX70CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.51 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464P-TZ1A (R454C hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR454C compressor — 0.67 kW cooling, 0.70 kW input, COP 0.95 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6YGXR35ME-TSN (R449A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR449A compressor — 60.8 kW cooling, 21.55 kW input, COP 2.82 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SZ115-4 (R404A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR404A compressor — 24.2 kW cooling, 9.66 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY70HSC (R134a hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.15 kW cooling, 0.10 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4522Z-XN3A (R404A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 5.4 kW cooling, 2.40 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YHNR32ML-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 57.8 kW cooling, 20.52 kW input, COP 2.82 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss VZH052CGM (R454B inverter scroll) CatalogCompressorsDanfossR454B compressor — 27.0 kW cooling, 9.48 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6210GK (R404A hermetic, MBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR404A compressor — 1.3 kW cooling, 0.74 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4440Z-AA1A (R448A hermetic, HBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 1.3 kW cooling, 0.51 kW input, COP 2.43 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YJNR39ML-TSE (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 68.6 kW cooling, 24.62 kW input, COP 2.79 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DCJ121T4A (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 35.7 kW cooling, 11.12 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEU6220GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 2.2 kW cooling, 1.30 kW input, COP 1.71 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4543N-TZ1A (R134a hermetic, HBP, Tecumseh Europe, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 11.6 kW cooling, 4.45 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YKNF68KL-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 19.9 kW cooling, 11.34 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSF485-9 (R32 scroll, 60 Hz, HT) CatalogCompressorsDanfossR32 compressor — 144.5 kW cooling, 42.08 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT6220Z (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 2.2 kW cooling, 1.08 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB5553ETZ (R22 hermetic, AC, Tecumseh Europe, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 13.0 kW cooling, 4.48 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YKNR32ME-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 57.8 kW cooling, 20.52 kW input, COP 2.82 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…275276277278279…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one