Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 6,601–6,624 of 10,248
Embraco NT6217GKV (R404A hermetic, MBP, EN12900, 60 Hz)
R404A compressor — 1.7 kW cooling, 1.03 kW input, COP 1.62 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6217U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 1.6 kW cooling, 0.69 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6217UV (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 1.8 kW cooling, 0.82 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6217Z (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 1.7 kW cooling, 0.80 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6217Z (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 2.0 kW cooling, 0.91 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6217ZV (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 1.6 kW cooling, 0.81 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6217ZV (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 2.0 kW cooling, 1.01 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220GK (R404A hermetic, MBP, EN12900, 50 Hz)
R404A compressor — 2.1 kW cooling, 1.20 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220GK (R404A hermetic, MBP, EN12900, 60 Hz)
R404A compressor — 2.1 kW cooling, 1.15 kW input, COP 1.79 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220GKV (R404A hermetic, MBP, EN12900, 50 Hz)
R404A compressor — 2.1 kW cooling, 1.20 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220GKV (R404A hermetic, MBP, EN12900, 60 Hz)
R404A compressor — 1.9 kW cooling, 1.10 kW input, COP 1.74 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 2.0 kW cooling, 0.85 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220UV (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 2.2 kW cooling, 0.93 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220Z (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 1.8 kW cooling, 0.90 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220Z (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 2.2 kW cooling, 1.08 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220ZV (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 1.8 kW cooling, 0.90 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6220ZV (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 2.2 kW cooling, 1.08 kW input, COP 2.03 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6222GK (R404A hermetic, MBP, EN12900, 50 Hz)
R404A compressor — 2.1 kW cooling, 1.19 kW input, COP 1.72 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6222GK (R404A hermetic, MBP, EN12900, 60 Hz)
R404A compressor — 2.7 kW cooling, 1.31 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6222GKV (R404A hermetic, MBP, EN12900, 50 Hz)
R404A compressor — 2.5 kW cooling, 1.40 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6222GKV (R404A hermetic, MBP, EN12900, 60 Hz)
R404A compressor — 2.4 kW cooling, 1.43 kW input, COP 1.66 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6222U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 2.3 kW cooling, 0.98 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6222UV (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 2.6 kW cooling, 1.14 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.
Embraco NT6224GK (R404A hermetic, MBP, EN12900, 50 Hz)
R404A compressor — 2.5 kW cooling, 1.28 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
Publishing here