Companies

Copeland Unclaimed

5,452 listings in HVAC Builder's catalog from Copeland's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Copeland has not claimed it.

Compressor maps by refrigerant: R407C 718, R448A 540, R407F 479, R407A 474, R404A 441, R449A 361, R410A 356, R134a 310, R22 277, R507 247, R454C 234, R455A 219, R513A 218, R454A 214, R290 145, R454B 106, R32 44, R450A 32, R1234yf 22, R452A 14, R245fa 1.

Copeland compressor ranges

Each range on a page of its own: every model code with its refrigerants, frequencies and ratings, and every model a page.

Are you Copeland?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Components

Showing 457–480 of 5,452

NameTypeRatingMarketsOpen in the builder
Copeland 6YRXF84KE-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsR454C compressor — 24.6 kW cooling, 14.06 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YRXR39ME-TSE (R448A Discus recip, 60 Hz, MD) CatalogCompressorsR448A compressor — 68.6 kW cooling, 24.62 kW input, COP 2.79 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YSNF84KE-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsR454C compressor — 24.6 kW cooling, 14.06 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YSNR39ME-TSE (R449A Discus recip, 60 Hz, MD) CatalogCompressorsR449A compressor — 68.6 kW cooling, 24.62 kW input, COP 2.79 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YUNF10ME-AWD (R454C Discus recip, 60 Hz, LD) CatalogCompressorsR454C compressor — 29.6 kW cooling, 16.88 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YUNR48ME-AWD (R454C Discus recip, 60 Hz, MD) CatalogCompressorsR454C compressor — 77.6 kW cooling, 28.59 kW input, COP 2.71 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YUXR48ME-AWD (R454C Discus recip, 60 Hz, MD) CatalogCompressorsR454C compressor — 77.6 kW cooling, 28.59 kW input, COP 2.71 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YVNF10ME-AWD (R454C Discus recip, 60 Hz, LD) CatalogCompressorsR454C compressor — 29.6 kW cooling, 16.88 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YVXF10ME-TSE (R407A Discus recip, 60 Hz, LD) CatalogCompressorsR407A compressor — 30.3 kW cooling, 17.38 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YVXR48ME-TSE (R404A Discus recip, 60 Hz, MD) CatalogCompressorsR404A compressor — 90.3 kW cooling, 36.23 kW input, COP 2.49 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YZNF10ME-TSE (R404A Discus recip, 60 Hz, LD) CatalogCompressorsR404A compressor — 40.9 kW cooling, 22.32 kW input, COP 1.83 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland 6YZNR48ME-TSE (R404A Discus recip, 60 Hz, MD) CatalogCompressorsR404A compressor — 90.3 kW cooling, 36.23 kW input, COP 2.49 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland AFE05C4E-IAA (R513A hermetic recip, 60 Hz, EA) CatalogCompressorsR513A compressor — 0.18 kW cooling, 0.19 kW input, COP 0.97 at -25/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland AFF07C1E-IAA (R450A hermetic recip, 60 Hz, EF) CatalogCompressorsR450A compressor — 0.18 kW cooling, 0.13 kW input, COP 1.38 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland AFM06C1U-IAZ (R290 hermetic recip, 50 Hz, LT) CatalogCompressorsR290 compressor — 0.20 kW cooling, 0.14 kW input, COP 1.40 at -30/45 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ARE13C4E-IAA (R450A hermetic recip, 60 Hz, HT) CatalogCompressorsR450A compressor — 0.38 kW cooling, 0.22 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ASE12C4E-IAA (R448A hermetic recip, 60 Hz, MT) CatalogCompressorsR448A compressor — 0.21 kW cooling, 0.20 kW input, COP 1.07 at -20/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ASM12C1U-RAA (R290 hermetic recip, 60 Hz, EM) CatalogCompressorsR290 compressor — 0.20 kW cooling, 0.12 kW input, COP 1.69 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland CF04K7ME-TF5 (R404A hermetic recip, 60 Hz, LT) CatalogCompressorsR404A compressor — 0.93 kW cooling, 0.83 kW input, COP 1.12 at -30/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland CR16K6E-PFV (R22 hermetic recip, 60 Hz, AC) CatalogCompressorsR22 compressor — 4.4 kW cooling, 1.49 kW input, COP 2.97 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland CRAQ-015E-TF5 (R407C hermetic recip, 60 Hz, AC) CatalogCompressorsR407C compressor — 5.1 kW cooling, 1.76 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland CRDQ-020E-TF5 (R407C hermetic recip, 60 Hz, AC) CatalogCompressorsR407C compressor — 6.6 kW cooling, 2.30 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland CREQ-022E-TF5 (R407C hermetic recip, 60 Hz, AC) CatalogCompressorsR407C compressor — 7.7 kW cooling, 2.58 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland CRGQ-025E-TF5 (R407C hermetic recip, 60 Hz, AC) CatalogCompressorsR407C compressor — 8.8 kW cooling, 3.05 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
‹ Previous1…1819202122…228Next ›

How the model reads against Copeland's data

Compressor maps converted from the vendor's own rating database5 452 maps (4 776 of the worldwide publication, 676 of the Asia and China publications listed for their region)every basis median within 3.1 % of the nomenclature; the vendor's polynomial substituted exactly, never refitted; each map's superheat and subcooling reference read off its own rating row (the ZW heat pumps at 5 K, the ZH/YH at 10 K, the Discus at 25 K, the small hermetics at a 40 °F return gas)
The compressor map's superheat/subcooling correction — AHRI-rated maps read at EN 12900 conditions99 R410A (13 models) + 22 R407C + 35 R134athe corrected map reads the guide's capacity at −0.1 % mean / 1.0 % RMS on R410A, flat across evaporating temperature, every model within ±1.6 %; R407C nominal +1.0 % / 1.8 % (with the subcooling measured from the bubble point, as AHRI 540 Appendix C reads it — +0.3 % when it was measured from the dew point, a difference inside the band either way); R134a +1.5 % / 1.8 %. The uncorrected polynomial reads +9 to +11 %. The R404A refrigeration scrolls, rated at a return gas rather than a superheat, read the guide's 20 °C return-gas tables at +0.7 % / 1.5 % from −15 to −5 °C (88 points) — there the correction is a one-per-cent matter either way. Not held: the heat-pump scrolls, for which the guide prints heating capacity — and one R407C row (ZRD72KCE) disagrees with its map by a quarter and is recorded as a catalogue fault
Drake Chillers PAC360D (30 HP, R407C and R404A), modelled — one air-cooled chiller on the catalog's maps of the compressor its sheet names, on both refrigerants it is sold on44 + the pinned cellthe pinned 45 °F row within −1.9 to +1.7 % on tons and −2.8 to 0 % on compressor power; every water row's ambient trend on both fluids, each cell against its row's 95 °F cell, at 1.2 % RMS on tons (worst 3.3) and 1.9 % on power (worst 4.7); and at 55 °F, the one leaving temperature both tables print, R404A's capacity over R407C's within −1.6 to −2.9 % of the sheet's ratio. Recorded, not held to the sheet: the sheet holds its evaporator at one approach whatever the duty ("selected upon requirements"), so one fixed conductance reads +6 to +11 % at 35 °F and −14 to −15 % at 65 °F; R404A's power over R407C's reads 4.9–8.7 % above the sheet's at 55 °F — the condenser model holds the refrigerant at its dew point, which credits R407C with half its 4.7 K glide, while the sheet's two tables are one condenser on the mean condensing temperature; the 0–25 °F R404A rows want glycol
KeepRite KEZ Generation D scroll condensing units, modelled — four frames on the catalog's maps of the Copeland scrolls the manual names, against its capacity tables on four refrigerants806 cells on 15 tables (KEZA009H8, KEZA050H8, KEZA150H8, KEZA150L8), four of them pinnedon the one condenser each, R404A within 0.5–1.1 % RMS (worst +3.4 %) and R407A, R407C and R448A within 1.3–3.7 % RMS (worst −6.9 and +6.7 %, both R448A), every table's mean within a point of the day's — a band no table read one ambient column or one suction row over meets; the 50 cells the manual shades for a 20 °F superheat limit read like the rest. What it tests is the four maps at their own rating basis more than the condenser: the tables are three significant figures with no power, and on three of the four frames the pinned airflow is not air the printed fans could move — through the stated coil it takes 1.9–4.1 times the air power they could give at the best static efficiency of a catalog axial fan of their size, so it stands for the conductance the tables ask for. The suction temperature reads as a dew point — taken as a mid-point the R448A tables read 10–11 % high. Across the manual's 18 cooler frames with a map the same reading runs 1.5–5.2 % RMS, KEZA061H8's R407C table apart (8–46 % under its map), and 10 of them ask a condenser their fans could not drive; the freezer tables mostly print more than their maps give near the ambient — three cannot be reached at any airflow, none is air its fans could move — and are recorded, not modelled

From the validation page; every row is held by a test.

Worked cases that run Copeland machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.