Companies

EVAPCO Unclaimed

992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 385–408 of 992

EVAPCO AT 212-4M28 cooling tower

Cooling tower — 4596 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 100.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-4M36 cooling tower

Cooling tower — 5621 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 125.3 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-4M40 cooling tower

Cooling tower — 5740 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 127.9 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-4N24 cooling tower

Cooling tower — 4513 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 101.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-4N28 cooling tower

Cooling tower — 5025 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 109.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-4N36 cooling tower

Cooling tower — 6173 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 137.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-4N40 cooling tower

Cooling tower — 6384 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 139.8 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-4O36 cooling tower

Cooling tower — 6629 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 146.9 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-4O40 cooling tower

Cooling tower — 6905 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 149.7 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-4P36 cooling tower

Cooling tower — 6879 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 155.6 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-4P40 cooling tower

Cooling tower — 7164 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 158.7 m³/s of air.

catalog
Cooling tower

EVAPCO AT 214-2G18 cooling tower

Cooling tower — 1932 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 62.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2G9 cooling tower

Cooling tower — 986 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 30.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2H12 cooling tower

Cooling tower — 1389 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 42.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2H14 cooling tower

Cooling tower — 1498 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 48.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2H18 cooling tower

Cooling tower — 2313 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 71.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2H9 cooling tower

Cooling tower — 1179 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 34.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2I12 cooling tower

Cooling tower — 1533 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 46.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2I14 cooling tower

Cooling tower — 2125 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 52.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2I18 cooling tower

Cooling tower — 2563 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 77.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2I9 cooling tower

Cooling tower — 1306 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 37.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2J12 cooling tower

Cooling tower — 1770 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 53.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2J14 cooling tower

Cooling tower — 1884 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 60.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 214-2J18 cooling tower

Cooling tower — 2949 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 88.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1…1516171819…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.