992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 25–48 of 992

EVAPCO AT 110-4J18 cooling tower

Cooling tower — 1840 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 44.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4K12 cooling tower

Cooling tower — 1533 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 36.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4K18 cooling tower

Cooling tower — 2015 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 49.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4L12 cooling tower

Cooling tower — 1634 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 39.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4L18 cooling tower

Cooling tower — 2160 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 52.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4M12 cooling tower

Cooling tower — 1722 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 41.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4M18 cooling tower

Cooling tower — 2287 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 55.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4N12 cooling tower

Cooling tower — 1796 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 43.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4N18 cooling tower

Cooling tower — 2497 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 60.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2I12 cooling tower

Cooling tower — 1227 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2I14 cooling tower

Cooling tower — 1310 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 36.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2J12 cooling tower

Cooling tower — 1463 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 38.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2J14 cooling tower

Cooling tower — 1573 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 41.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2J18 cooling tower

Cooling tower — 1923 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 52.0 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-2K12 cooling tower

Cooling tower — 1595 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 42.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2K14 cooling tower

Cooling tower — 1726 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 45.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2K18 cooling tower

Cooling tower — 2178 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 56.9 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-2K20 cooling tower

Cooling tower — 2011 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 58.5 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-2L12 cooling tower

Cooling tower — 1713 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 45.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2L14 cooling tower

Cooling tower — 1862 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 49.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2L18 cooling tower

Cooling tower — 2300 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 61.2 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-2L20 cooling tower

Cooling tower — 2217 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 62.8 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-2M12 cooling tower

Cooling tower — 1814 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 47.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-2M14 cooling tower

Cooling tower — 1972 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 52.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1234…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.