992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.
Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Showing 49–72 of 992
Cooling tower — 2427 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 64.8 m³/s of air.
Cooling tower — 2383 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 66.5 m³/s of air.
Cooling tower — 2673 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 71.0 m³/s of air.
Cooling tower — 2738 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 72.7 m³/s of air.
Cooling tower — 2975 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 78.0 m³/s of air.
Cooling tower — 1385 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.3 m³/s of air.
Cooling tower — 1507 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 36.2 m³/s of air.
Cooling tower — 1621 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 37.8 m³/s of air.
Cooling tower — 1774 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 41.1 m³/s of air.
Cooling tower — 2138 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 51.2 m³/s of air.
Cooling tower — 1770 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 41.3 m³/s of air.
Cooling tower — 1923 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 45.0 m³/s of air.
Cooling tower — 2392 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 56.0 m³/s of air.
Cooling tower — 2348 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 57.5 m³/s of air.
Cooling tower — 1902 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 44.3 m³/s of air.
Cooling tower — 2064 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 48.3 m³/s of air.
Cooling tower — 2546 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 60.1 m³/s of air.
Cooling tower — 2563 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 61.7 m³/s of air.
Cooling tower — 2020 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 47.0 m³/s of air.
Cooling tower — 2195 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 51.1 m³/s of air.
Cooling tower — 2690 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 63.7 m³/s of air.
Cooling tower — 2730 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 65.3 m³/s of air.
Cooling tower — 2401 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 56.0 m³/s of air.
Cooling tower — 2957 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 69.7 m³/s of air.
| Cooling-tower model, zero fitted parameters | 856 | mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table) |
| Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it | 45 945 over 992 machines | mean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3 |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.