992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 97–120 of 992

EVAPCO AT 112-4O18 cooling tower

Cooling tower — 3317 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 73.4 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4O20 cooling tower

Cooling tower — 3453 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 75.3 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4P18 cooling tower

Cooling tower — 3439 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 77.8 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4P20 cooling tower

Cooling tower — 3580 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 79.8 m³/s of air.

catalog
Cooling tower

EVAPCO AT 114-2K24 cooling tower

Cooling tower — 2712 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 75.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-2L24 cooling tower

Cooling tower — 2997 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 80.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-2M24 cooling tower

Cooling tower — 3163 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 85.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-2N24 cooling tower

Cooling tower — 3422 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 94.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-2O24 cooling tower

Cooling tower — 3676 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 100.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-3K24 cooling tower

Cooling tower — 3102 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 74.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-3L24 cooling tower

Cooling tower — 3396 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 79.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-3M24 cooling tower

Cooling tower — 3558 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 84.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-3N24 cooling tower

Cooling tower — 3908 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 92.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-3O24 cooling tower

Cooling tower — 4167 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 99.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-3P24 cooling tower

Cooling tower — 4416 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 104.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-4K24 cooling tower

Cooling tower — 3382 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 72.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-4L24 cooling tower

Cooling tower — 3654 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 78.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-4M24 cooling tower

Cooling tower — 3821 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 82.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-4N24 cooling tower

Cooling tower — 4149 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 90.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-4O24 cooling tower

Cooling tower — 4373 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 97.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-4P24 cooling tower

Cooling tower — 4627 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 103.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-4Q24 cooling tower

Cooling tower — 4973 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 110.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-5K26 cooling tower

Cooling tower — 4395 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 94.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-5L26 cooling tower

Cooling tower — 4723 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 101.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1…34567…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.