992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 121–144 of 992

EVAPCO AT 114-5M26 cooling tower

Cooling tower — 5004 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 107.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-5N26 cooling tower

Cooling tower — 5464 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 117.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 114-5O26 cooling tower

Cooling tower — 5836 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 125.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-2E4 cooling tower

Cooling tower — 145 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 4.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-2E9 cooling tower

Cooling tower — 333 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 10.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-2F12 cooling tower

Cooling tower — 504 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 14.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-2F4 cooling tower

Cooling tower — 171 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 5.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-2F6 cooling tower

Cooling tower — 250 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 7.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-2F9 cooling tower

Cooling tower — 394 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 11.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-2G12 cooling tower

Cooling tower — 600 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 17.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-2G6 cooling tower

Cooling tower — 294 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 8.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-3E4 cooling tower

Cooling tower — 162 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 4.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-3E9 cooling tower

Cooling tower — 377 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 9.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-3F12 cooling tower

Cooling tower — 565 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 14.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-3F4 cooling tower

Cooling tower — 188 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 5.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-3F6 cooling tower

Cooling tower — 280 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 7.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-3F9 cooling tower

Cooling tower — 438 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 11.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-3G12 cooling tower

Cooling tower — 657 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 16.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 14-3G6 cooling tower

Cooling tower — 324 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 8.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-2G18 cooling tower

Cooling tower — 999 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 30.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-2G9 cooling tower

Cooling tower — 495 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 15.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-2H12 cooling tower

Cooling tower — 719 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 21.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-2H14 cooling tower

Cooling tower — 762 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 23.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-2H18 cooling tower

Cooling tower — 1192 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 34.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1…45678…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.