992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 169–192 of 992

EVAPCO AT 17-3J18 cooling tower

Cooling tower — 1704 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 42.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-3J9 cooling tower

Cooling tower — 846 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 21.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-3K12 cooling tower

Cooling tower — 1130 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 29.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-3K14 cooling tower

Cooling tower — 1406 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 31.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-3K18 cooling tower

Cooling tower — 1884 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 46.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-3K9 cooling tower

Cooling tower — 933 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 23.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-3L12 cooling tower

Cooling tower — 1222 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 31.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-3L14 cooling tower

Cooling tower — 1183 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 34.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-3M14 cooling tower

Cooling tower — 1380 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 36.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4G18 cooling tower

Cooling tower — 1266 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 29.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4G9 cooling tower

Cooling tower — 627 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 14.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4H12 cooling tower

Cooling tower — 881 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 21.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4H14 cooling tower

Cooling tower — 977 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 23.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4H18 cooling tower

Cooling tower — 1455 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4H9 cooling tower

Cooling tower — 719 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 16.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4I12 cooling tower

Cooling tower — 964 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 23.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4I14 cooling tower

Cooling tower — 863 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 25.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4I18 cooling tower

Cooling tower — 1586 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 36.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4I9 cooling tower

Cooling tower — 784 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 18.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4J12 cooling tower

Cooling tower — 1091 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 26.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4J14 cooling tower

Cooling tower — 1222 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 28.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4J18 cooling tower

Cooling tower — 1788 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 41.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4J9 cooling tower

Cooling tower — 885 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 20.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 17-4K12 cooling tower

Cooling tower — 1187 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 28.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1…678910…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.